GV4 Series | Approved Applications Compliance Guide |
Bosch Security Systems, Inc. | 3/12 | F01U266055-01 13
2.4 Enclosures
Bosch Security Systems offers three optional
enclosures for the control panel. Sections 2.4.1
D8103 Enclosure, 2.4.2 D8108A Enclosure, and
2.4.3 D8109 Red Fire Enclosure describe the three
options.
2.4.1 D8103 Enclosure
The D8103 is suitable for residential fire and
burglary installations and commercial burglary
applications that do not require attack resistance
or the approval by Factory Mutual (FM) or New
York City – Materials and Equipment Acceptance
(NYC-MEA). Refer to Table 3 on page 16 for
acceptable applications.
2.4.2 D8108A Enclosure
The D8108A is attack resistant and intended
primarily for UL commercial burglar alarm and
mercantile safe and vault applications requiring a
local bell. This enclosure can be used in any
burglar or fire alarm application where the D8109
Enclosure is suitable.
The D8108A, with some modification, can be
used for bank safe and vault applications as
described in Section 2.2 Bank Safe and Vault
Applications on page 4. UL lists the D8108A for all
commercial fire alarm applications. It is approved
by FM, CSFM, and the NYC-MEA.
2.4.3 D8109 Red Fire Enclosure
Generally, the D8109 is used for fire alarm
applications. UL lists the D8109 for all
commercial fire alarm applications. It is approved
by FM, CSFM, and the NYC-MEA.
All references to NFPA and related
requirements are based on
compliance with the NFPA 72,
National Fire Alarm Code. Because
installation specifications are
generally based on a specific edition
of a standard that was legally adopted
by the authority having jurisdiction
(AHJ), consult with the appropriate
AHJ for confirmation.
3.0 UL/NFPA Compliant
Installations
3.1 Required Components
(D9412GV4/D7412GV4 only)
To install a D9412GV4 or D7412GV4 that is UL
and NFPA compliant, the following items must be
included:
D8109 Red Fire Enclosure
D192G Bell Supervision Module
D928 Dual Phone Line Module
D8004 Transformer Enclosure
Ground Fault Detect enabled on the control
panel
Refer to Table 3 on page 16 for specific
application installation requirements.
3.2 Installing Combination Fire and
Intrusion Alarm Systems
When installing a combination fire and
intrusion alarm system, you must
adhere to the following requirements
in order to comply with Sections 56.1,
56.2, and 56.4 of the 9
th
Edition of UL
864.
The D7212GV4 is not listed for
commercial fire applications.
3.2.1 SDI Bus Devices
Keypads (Command Centers)
Keypads used exclusively for intrusion system
operation are not allowed. Keypads connected to
the D9412GV4 and D7412GV4 Control Panels
must include the scope of all fire-related points
and must be assigned to include Area 1 in the
scope.
Interface Modules
Connect the DX4020 Network Interface
Module and the D9210C Access Control
Interface Module to the SDI bus only if the
interface module is located within the control
panel enclosure or in a separate enclosure in
the same room within 6.1 m
(20 ft) of the main control panel.
Route all SDI bus wiring in EMT (electrical
metallic tubing) conduit.