• Full function command menu including custom
functions
• Authority by area and 16‑character name for each
user
• 14 custom authority levels control user’s authority to
change, add, or delete passcodes or access control
credentials; to disarm or bypass points; and to start
system tests
Area Configurations
Area programming offers a wide selection of different
system configurations. Each area is assigned an
account number to define annunciation, control, and
reporting functions. Multiple areas can be linked to a
shared area which is automatically controlled (hallway
or lobby). Area arming can be conditional on other
areas (master or associate). Any area can be
configured for perimeter and interior arming, not
requiring a separate area for this function.
Two Man Rule
Two Man Rule provides added security by requiring:
• Two people present at opening
• Two unique passcodes on the same keypad to disarm
an area
Without the second passcode, the system denies
entry.
Early Ambush
Early Ambush requires two passcode entries on the
same keypad. Enter the same passcode twice or have
two unique passcodes, depending on the
configuration. The first entry disarms the area and the
second entry stops a timer programmed to send a
duress event. If the second entry does not occur
within the programmed time, the system generates a
duress event. Early Ambush allows users to inspect the
premises and use the system to confirm that the area
is safe to enter, providing added security.
Easy Exit Control
The D7412GV3 Control Panel changes from one armed
state to another armed state without disarming. For
example, if you change the state from Master Arm to
Perimeter Arm, the control panel complies and reports
the change. Easy Exit Control reduces the number of
keystrokes, simplifying system operation.
Programmable Passcode‑controlled Menu List
The system prompts users to enter a passcode prior to
viewing the keypad menu. The keypad display shows
the user the menu options allowed according to the
user’s authority level. Passcode‑controlled menus
provide users only with the options and information
pertinent to them, simplifying system operation.
Passcode Follows Scope
Use Passcode Follows Scope to restrict passcode
arming and disarming to the keypad’s immediate local
area, even if the keypad can report events from other
areas. Passcode Follows Scope simplifies the arming
and disarming procedure without limiting any other
keypad capabilities.
Invisible Walk Test
A menu item allows the user to test invisible 24‑hour
points within the scope of the keypad without sending
a report to the central station.
Door‑Activated Custom Function
A custom function activates when user credentials are
presented to a D9210B door controller's reader. The
custom function behaves as though the user
performed a function at the keypad associated with
the door controller.
Passcodes
User passcodes contain three to six digits. Assign each
user one of 14 customized authority levels in each
area. Restrict passcodes to operate only during certain
times.
The Two Man Rule and Early Ambush options require
two passcodes, providing additional security in
financial establishments such as banks.
Communications
The D7412GV3 Control Panel prioritizes and sends
reports in Contact ID or Modem IIIa
2
communications
formats to four route groups. Each group has a
programmable primary and backup destination.
The D7412GV3 provides flexible communications for
most central stations with reporting capabilities such
as:
• Individual point numbers
• Opening or closing reports by user and area number
• Remote programming attempts
• Diagnostic reports
The D7412GV3 uses the DX4020 Ethernet Network
Interface Module and/or the ITS‑DX4020‑G GPRS/GSM
Communicator to communicate with the Conettix
D6600 and D6100i Communications Receiver/
Gateways. Using Conettix IP communication offers a
secure path that includes anti-replay/anti-substitution
features and provides enhanced security with
encryption. Both the DX4020 and ITS‑DX4020‑G can
be used for remote programming.
Security and Fire Detection
The D7412GV3 Control Panel provides eight on‑board
points, and up to 67 additional off‑board points
(depending on model and expansion interfaces). You
can program individual points to monitor all types of
burglar alarms, fire alarms, and supervision devices.
Commercial Wireless
The Commercial Wireless platform, powered by
Inovonics wireless mesh network technology, ensures
superior range, reliability, and scalability for
commercial applications. Using a wide range of
transmitters and repeaters, this proven technology
provides flexibility and performance to meet the most
stringent requirements. This exclusive protocol is
available only on Commercial Wireless products.
The Commercial Wireless platform sends redundant
information on several multi-frequency channels within
the FCC Part 15 900 MHz band, providing superior
range and reliability. In comparison, systems that use a
2
| D7412GV3 Control Panel
Komentarze do niniejszej Instrukcji