DX4020-EXP | Installation Guide | 6. IP Programming EN | 12
Bosch Security Sys | 8/04 | F01U002192B
16. Press [Enter] to accept the default I/F Mode of
(4C). If is not the default, type [4c] [ENTER] to
change it.
17. Press [ENTER] to accept the default Flow of (00).
If 00 is not the default, type [00] [ENTER] to cange
it.
18. Type a unique port number for the particular LAN
that the device is connected to and then press
[ENTER].
Datagram Type 07 must be used if the
unique port number is not the same one
used for the D6680.
To use Datagram 02 or 07, you must have
firmware version 1.5d or greater in the
Xport module. See DeviceInstaller
Operation and Installation Guide
(P/N: 4998138688) for more information.
The port number displayed here is an
example and might not be the same.
19. Press [Enter] to accept the default ConnectMode of
(CC). If CC is not the default, type [cc] [ENTER]
to change it.
20. Enter the appropriate Datagram value based on
your control panel type:
- DS7240V2/DS7220V2: Enter [02] and skip to
Step 23.
- DS7400XiV4+: Enter [07] and go to Step 21.
For more information on Datagram Types,
see the D6600 System Guide
(P/N: 4998122712).
21. Press [ENTER] four times to specify 0.0.0.0 for
remote IP address.
22. Enter the same port number that was used for the
D6680.
23. To enable encryption, select 6- Security from the
main menu and follow the next steps.
If encryption is enabled on the DX4020 it
must be enabled at the D6680-E120 with
the same key.
The software revision of the Network
Interface Module attached to the DX4020
must be 1.5d or greater. To check the
version, telnet the unit and the version is
displayed for five seconds before pressing
[ENTER].
Figure 16: DX4020 Encryption
24. At Disable SNMP (N) N press [ENTER].
25. At SNMP Community Name ( ): press [ENTER].
26. At Disable Telnet Setup (N) N press [ENTER].
27. At Disable Port 77FEh (N) N press [ENTER].
28. At Disable Web Server (N) N press [ENTER].
29. At Disable ECHO ports (Y) Y press [ENTER].
30. At Enable Encryption (N) press [Y].
31. At Key length in bits (0), type 128 and press
[ENTER].
32. Change keys (N) press ‘Y’.
33. Enter the bytes programmed in the D6680. These
16 bytes (32 characters) should match. Default
value is 01-02-03-04-05-06-07-08-09-10-11-12-13-
14-15-16.
34. At Enable Enhanced Password (N) press [ENTER].
35. Select 9 at the main menu to save and close telnet
session.
36. A message is displayed the connection was lost.
37. Click OK to close the Telnet window.
38. To confirm that the IP address had been
configured properly, PING the IP Address and
check for a response.
39. At the C:\> prompt, type PING <IP Address>
then press [ENTER].