Correction of Malfunctions
Accessories
For more information on the complete quality accessories
program, please refer to the Internet under
www.bosch-pt.com or contact your specialist shop.
Problem Cause Corrective Measure
The pneumatic tool is ready for operation, but no staples
(GTK 40) or brads (GSK 50) are discharged.
A staple (GTK 40) or a brad (GSK 50) has become jammed in
the shot duct.
–Clear the jam.
(See “Clearing Jams”, page 16)
The magazine slider is 11 defective. Clean and lubricate the magazine slider 11 as required
and make sure that the magazine 8 is not dirty/soiled.
The spring of the magazine slider is too week or defective. Contact an authorised service agent for Bosch power
tools.
Have the component replaced there.
The fasteners being used are not permitted. Use only original accessories.
Only the fasteners (nails, staples, etc.) specified in ta-
ble “Technical Data” may be used.
The magazine 8 is empty. Refill the magazine.
(See “Loading the Magazine”, page 15)
The staples (GTK 40) or brads (GSK 50) are discharged very
slowly and with too little pressure.
The rated pressure of the compressed-air supply is too low. Increase the compressed-air supply. 8 bar may not be
exceeded.
The driver blade is damaged. Use only the lubricants recommended by Bosch.
(See “Lubricating the Pneumatic Tool”, page 16)
The sealing ring of the piston is worn or damaged. Contact an authorised service agent for Bosch power
tools.
Have the component replaced there.
The buffer is worn. Contact an authorised service agent for Bosch power
tools.
Have the component replaced there.
The length and diameter of supply-air hose 17 do not corre-
spond with the data of this pneumatic tool.
Use a supply-air hose with the correct dimensions.
(See “Technical Data”, page 14)
The supply-air hose 17 is bent/creased. Correct the bend/crease in the supply-air hose.
The staples (GTK 40) or brads (GSK 50) are driven in too
deep.
The rated pressure of the compressed-air supply is too high. Reduce the compressed-air supply. 5 bar may not be
fallen below.
The depth stop is set too deep. Adjust the depth stop to the desired depth.
(See “Adjusting the Depth Stop”, page 16)
The buffer is worn. Contact an authorised service agent for Bosch power
tools.
Have the component replaced there.
The staples (GTK 40) or brads (GSK 50) are not driven in
deep enough.
The rated pressure of the compressed-air supply is too low. Increase the compressed-air supply. 8 bar may not be
exceeded.
The depth stop is set too high. Adjust the depth stop to the desired depth.
(See “Adjusting the Depth Stop”, page 16)
The length and diameter of supply-air hose 17 do not corre-
spond with the data of this pneumatic tool.
Use a supply-air hose with the correct dimensions.
(See “Technical Data”, page 14)
The supply-air hose 17 is bent/creased. Correct the bend/crease in the supply-air hose.
The pneumatic tool skips staples (GTK 40) or brads (GSK 50)
or has a too large cycle feed.
The fasteners being used are not permitted. Use only original accessories.
Only the fasteners (nails, staples, etc.) specified in ta-
ble “Technical Data” may be used.
The magazine 8 is not operating correctly. Clean and lubricate the magazine slider 11 as required
and make sure that the magazine 8 is not dirty/soiled.
The spring of the magazine slider is too week or defective. Contact an authorised service agent for Bosch power
tools.
Have the component replaced there.
The sealing ring of the piston is worn or damaged. Contact an authorised service agent for Bosch power
tools.
Have the component replaced there.
The staples (GTK 40) or brads (GSK 50) frequently jam in the
shot duct.
The fasteners being used are not permitted. Use only original accessories.
Only the fasteners (nails, staples, etc.) specified in ta-
ble “Technical Data” may be used.
Contact an authorised service agent for Bosch power
tools.
The driven staples (GTK 40) or brads (GSK 50) are bent.
The driver blade is damaged. Contact an authorised service agent for Bosch power
tools.
Have the component replaced there.
Contrary to working with normal operating speed, the staples
(GTK 40) or brads (GSK 50) are not driven in deep enough
enough at higher operating speeds.
The interior diameter of the supply-air hose is too low. Use a supply-air hose with the correct dimensions.
(See “Technical Data”, page 14)
The compressor is not suitable for fast operating speeds. Use a compressor that is sufficiently dimensioned for
the number of connected pneumatic tools and the op-
erating speed.