Bosch AMAX panel 2000 ICP-AMAX-P Instrukcja Obsługi Strona 25

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 32
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 24
AMAX panel 2000 / AMAX panel 2000 EN Specification | en 25
Robert Bosch Engineering and Business Solutions LimitedQuick Reference Guide F.01U.241.128 | V2 | 2011.11
Output Voltage Range under AC line input: 12,82 VDC to
13,9 VDC
500mA maximum
Vpp (max) 675mV
Option Bus: Nominal Output Voltage under AC line input: 13,5 VDC +3%
/ -5%
Output Voltage Range under AC line input: 12,82 VDC to
13,9 VDC
500mA maximum
RF Power Output 5VDC / 100mA maximum
Panel PCB Quiescent current maximum 100mA
Battery: D126 (12V/7 Ah) sealed, lead acid rechargeable
Low battery condition is below 11,8 VDC
Minimum battery condition is 10,8VDC
Maximum auxiliary current to recharge standby battery to
80% within 72h:
12 V/7 Ah Battery: 550 mA
Certification: EN 50131-3 Grade-2 Env-II
Keypads:
IUI-AMAX-LED8 (8Zone LED Keypad)
Relative Humidity: 10%-95%
Operating Temperature: -10°C - +55°C
Input Voltage range: 10VDC - 14VDC
Current Consumption standby 24mA
maximum 50mA
Cable requirements: four wire, unshielded and shielded 0,6-0,8mm
maximum length 150m
EN type: B
IUI-AMAX-LCD8 (8Zone LCD Keypad)
Relative Humidity: 10%-95%
Operating Temperature: -10°C - +55°C
Input Voltage range: 10VDC - 14VDC
Current Consumption standby 18mA
maximum 60mA
Cable requirements: four wire, unshielded and shielded 0,6-0,8mm
maximum length 150m