2 of 6
INSTALLATION OVERVIEW
1. Install the security system and program the panel for the RS-232 interface.
2. Install the DX4010I and set the dip switches.
3. Run a Cat5 wire from the g! Controller to the security panel and test the cable.
4. Test the security panel, zone sensors and keypads for functionality.
5. Connect the g! Controller to the panel electrically.
6. Configure the g! communication device and security panel and confirm communication between the
panel and the g! Controller.
7. Fault zones in the system and then confirm that the g! Viewer shows the faulted zones.
8. Test the arming and disarming capability from a computer or touch screen and confirm history
function.
CONNECTION DIAGRAM
B
ILL OF MATERIALS
# Device Manufacturer Part Number Protocol Connector Type Notes
1 Co ntrol P anel Radio nics D9412G/D7412G RS-232 Vario us
2 Serial Interface M odule Radionics DX4010I RS-232 DB-9 M ale x Wires
3 DB9F to RJ45 Null Adapter Elan HA-CB-328 RS-232 DB-9 Female X RJ-45 Female
4 Cat5 Cable Assy. Installer N/A RS-232 RJ-45 M ale X RJ-45 M ale M ust terminate all 8 co nducto rs
5 Co ntro ller Elan Vario us (Ex. HC-12) RS-232 RJ-45 Female
Komentarze do niniejszej Instrukcji