Bosch DS7445 Podręcznik Użytkownika

Przeglądaj online lub pobierz Podręcznik Użytkownika dla Systemy kontroli dostępu bezpieczeństwa Bosch DS7445. Bosch DS7445 User`s guide Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 48
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
DS7400Xi (version 3+) Security System
User’s Guide
An instruction guide for your alarm system
when used with a DS7447 or DS7445 keypad
Alpha “English Display” Keypad
LED Keypad
DS7447 DS7445
Armed
Status
Power
Fire
Perimeter
Supervisory
Bell Silenced
Trouble
12345678
123
456
789
0
*
#
On
No
Entry
System
Reset
Bypass
Only
Perimeter
Off
Armed
Status
Power
Fire
123
456
789
0
*
#
On
No
Entry
System
Reset
Bypass
Only
Perimeter
Off
Przeglądanie stron 0
1 2 3 4 5 6 ... 47 48

Podsumowanie treści

Strona 1 - User’s Guide

DS7400Xi (version 3+) Security SystemUser’s GuideAn instruction guide for your alarm systemwhen used with a DS7447 or DS7445 keypadAlpha “English Disp

Strona 2 - System Overview

- 10 -This chart explains the procedure for Force Arming yoursystem if one or more zones are faulted.When one or more zones are faulted, the system ma

Strona 3 - Table of Contents

- 11 -This chart explains the procedure for bypassing a faulted zone prior to arming the system.There may be occasions when it is desirable or necessa

Strona 4 - Day to Day Operations

- 12 -Each partition can be programmed to automatically arm once per day. To program the Automatic Arming time, perform the following:Automatic Arming

Strona 5 - These Li

- 13 -Automatic DisarmingEach partition can be programmed to automatically disarm once per day. To program the Automatic Disarming time, perform thefo

Strona 6 - Force Arming

- 14 -This section explains how to delay the Automatic Arming Time.To inform occupants that the system is about to arm, a pre-arming period will begin

Strona 7 - ** = DS7445 only

- 15 -This section explains how to cause the system to arm after a specified number of hours.Delayed arming is simply causing the system to arm after

Strona 8 - Quick Arming your System

- 16 -This chart explains the procedure for turning ON and turning OFF Chime Mode.Chime Mode causes the keypad sounders to beep each time a Perimeter

Strona 9 - Action Desired

- 17 -This chart explains the procedure for activating devices that require an Access Control PIN.Your system may use a keypad key sequence to activat

Strona 10 - Force Arming your System

- 18 -This chart will guide you through the steps necessary to Change the System Date.You should write down your entries before you enter the Master C

Strona 11 - Zone Bypass

- 19 -This chart will guide you through the steps necessary to Change the Expiration Date for Temporary PINs.You should write down your entries before

Strona 12 - Automatic Arming

- 2 -Congratulations on the installation of your new security system. No other investment can provide such peace of mind. Welcometo the DS7400Xi intr

Strona 13 - Automatic Disarming

- 20 -This chart will guide you through the steps necessary to change the Time displayed at the keypads.You should write down your entries before you

Strona 14 - Delaying Automatic Arming

- 21 -Identifying Alarm SoundsYour alarm system may be programmed for a steady alarm soundor a pulsed alarm sound. It is important to learn the differ

Strona 15 - Delayed Arming

- 22 -This chart explains the proper procedure for disarming under Duress.Ask your installer if the Duress feature has been activated.A Duress code is

Strona 16 - Chime Mode

- 23 -The Emergency Alarm Keys [A], [B], and [C] may generate Fire, Special Emergency and Panic Alarms ifprogrammed by the installer. Ask your install

Strona 17 - Access Control

- 24 -Fire ResetDuring a fire alarm, exit the premises immediately. When youhave determined there is no fire, you must silence the bells/sirens before

Strona 18 - Changing the Date

- 25 -WARNING: No fire detection device or system should be considered 100 percent foolproof.This fire alarm system can provide early warning of a de

Strona 19

- 26 -• Provide a barricade between family members and fire, smokeand toxic gases (i.e. close all bedroom doors before retiring).• Children should be

Strona 20 - Changing the Time

- 27 -General InformationWhen programming Personal Identification Numbers, it is help-ful to know the following terms:• PIN: Personal Identification

Strona 21 - Emergency Procedures

- 28 -This chart will guide you through the steps necessary to change a PIN.You should write down your entries before you enter the Master Code Progra

Strona 22

- 29 -PIN Authority Levels0 = Master:Can enter all commands, add or change PINs in assignedpartitions, change the time and date, bypass, arm, disarm,p

Strona 23 - 12345678

- 3 -System Overview ... 2Table of Contents ...

Strona 24 - Fire Reset / Fire Trouble

- 30 -Error DisplaysThis chart explains the procedure for reading Error messages when the green Power Light is flashing.Note: System faults may be rea

Strona 25 - Fire Safety

- 31 -System FaultsSystem faults are designated as follows:System Faults are designated as follows:[#] [8] [7] will display[#] [8] [9] will displayRAM

Strona 26 - Fire Safety (continued)

- 32 -This chart explains the procedure for performing a Zone Test.It is recommended that the system be tested weekly.The Zone Test is used to confirm

Strona 27

- 33 -This chart explains the procedure for performing a Battery Test.If a power failure occurs, your control panel has a built-in battery that will c

Strona 28

- 34 -This chart explains the procedure for performing a Communicator Test.This test is available only if your system transmits alarms and system info

Strona 29

- 35 -Testing your System (continued)This chart explains the procedure for performing a Fire Walk Test.This test is used to confirm that Smoke detecto

Strona 30 - Error Displays

- 36 -This chart explains the procedure for performing an Event History Readback.The History Buffer stores the last 400 events in memory. The DS7447 c

Strona 31 - System Faults

- 37 -The Master Keypad - DS7447 onlyYour system may include a Master keypad.A Master keypad is a DS7447 keypad programmed to give a user access to al

Strona 32 - Testing your System

- 38 -This chart will help you understand what each Light function of the Master keypad represents.Master Keypad Displays - DS7447 onlyLight OffFlashi

Strona 33

- 39 -This chart will help you to Arm from the Master keypad.Arming from the Master Keypad - DS7447 onlyArming from the Master keypadArming all thePar

Strona 34

- 4 -This chart will help you understand what each Light/LEDon a Standard keypad represents.(For Master keypad operation, see page 37.)The DS7447 is a

Strona 35 - PIN + [#] [9] [1]

- 40 -This chart will help you to Disarm from the Master keypad.Disarming from the Master Keypad - DS7447 onlyDisarming from the Master keypadDisarmin

Strona 36 - Event History Readback

- 41 -Single Partition Mode is used to control partitions on a “one at a time/one by one” basis from the Master keypad.To enter the Single Partition M

Strona 37

- 42 -Access Control PINAn Access Control PIN is a specialcode used to activate electric doorlocks or other mechanisms connectedto the control panel t

Strona 38 - Error Displa

- 43 -Installing CompanyThe Installing Company is the companythat physically installed the system. Itmay or may not be the same companywho monitors th

Strona 39 - from the Master ke

- 44 -IndexAccess Control ... 17Access Control PIN ... 17, 42Alarm Sounds ...

Strona 40 - Disarmin

- 45 -Maintenance and ServiceThe system should be tested weekly to ensure it is functioning properly. If problems are detected in testing or changes a

Strona 41

- 46 -Quick Reference Guide (continued)Zone Protection65 _______________66 _______________67 _______________68 _______________69 _______________70 ___

Strona 42 - Glossary

- 47 -Audible Alarm Signalling Device SoundsIntrusion ( ) Pulse ( ) ContinuousFire ( ) Pulse ( ) ContinuousKeypad Supplemental Alarm [B] Key(

Strona 43 - Glossary (continued)

Commands for Other System FeaturesChime Mode [PIN] + [#] [7]Zone Test [PIN] + [#] [8] [1]Battery Test [PIN] + [System Reset]Communicator Test [PIN] +

Strona 44

- 5 -Volume Control: The keypad sounder volume can be adjusted using the [1] and [4] keys along with the [*] key.- Hold the [*] key while pressing th

Strona 45 - Quick Reference Guide

- 6 -This chart explains the five normal ways to arm the system from a Standard keypad. (For a Master keypad see page 37.)The green Status Light must

Strona 46

- 7 -Note: In commercial burglar alarm applications for U.L. Listed systems, a ring-back indicationand bell test should be heard after arming (closin

Strona 47

- 8 -This chart explains four ways to quick arm the system from a Standard keypad.If Quick Arming is not used, a PIN must be entered at the beginning

Strona 48 - Company at the above numberr

- 9 -This chart explains proper procedures for disarming and/or silencing alarms from a Standard keypad.(To disarm from a Master keypad, see page 40.)

Komentarze do niniejszej Instrukcji

Brak uwag