Contrast Adjust
Displays the Contrast Adjust menu which provides
two adjustment scales: one for the softkey display,
and one for the status display. Control each
adjustment scale with the adjacent softkey buttons
(as indicated by the arrows in the menu).
Generally, the buttons to the right of each scale
decrease the contrast (make the display lighter),
while the buttons to the left increase the contrast
(make the display darker). The indicator on the
scale is incremented (moved) one step for each
press of the softkey. The indicator wraps around
when either limit is reached. When the desired
contrast level is reached, press ENTER to exit the
submenu and store the values. Press CLR at any
time to reset the contrast to the presently stored
value. Pressing MON + CLR (simultaneously, at
any time while using the keyboard) resets the
contrast to the center position of the scale.
NOTE: It is possible to adjust the contrast to a level
where the text cannot be seen. If this happens, simply
continue pressing the softkey until the text reappears
OR press CLR to restore the display to the presently
stored values.
Key Click On/Off
Toggles between audible sound at each key click
and no sound at each click. Upon pressing the key,
the softkey descriptor indicates whether key click is
on or off.
Display Inverse
Toggles the display between black-on-white display
or white-on-black display. Upon pressing the key,
the softkey descriptor indicates whether display
inverse is on or off.
4CONTROLLING ALLEGIANT
SERIES VIDEO SWITCHERS
NOTE: This section applies to KBD-Universal Model
ONLY.
4.1 The Allegiant Main Control Menu
4.1.1 Accessing the Allegiant Main Control Menu
1. Press PROD to put the keyboard in Product Selection
Mode. The Product Selection menu appears in the
softkey display.
2. Press the Allegiant or ADIM softkey button, and
observe that the status display shows the Allegiant
mode.
3. While in Allegiant mode, keyboard operators can
use a convenient “Go Back” feature. To go back to
the previously selected camera, simply press and
hold the “CLR” key for more than 1 second.
FIGURE 4-1 Status Display in Allegiant Mode
IMPORTANT NOTE REGARDING USER LOG-ON:
Depending on the setting of the Allegiant Switcher, it
may be necessary to perform a log-on procedure to
gain control of the switcher (i.e. to gain access to the
Allegiant Main Control menu).
If log-on information is required, the status
display requests a USER NUMBER. Enter
the number using the keypad, and press
ENTER.
The status display requests a PASSWORD.
Enter the password using the keypad, and
press ENTER.
If an invalid user number or password is
entered, the request for log-on is redisplayed.
•Following successful user log-on, the softkey
display shows the Allegiant Main Control menu
as in FIGURE 4-2.
If user log-on is NOT required, the softkey
display shows USER LOGGED ON (briefly),
and then displays the Allegiant Main Control menu.
FIGURE 4-2 Allegiant Main Control Menu
14
13
12
User
Exit Log Off
Device Command
Lockout Script
Program Camera
Sequence Control
Alarm User
Control Functions
Load ADIM
Sequence Controls
Hold Start
Sequence Sequence
< Previous Next >
< Sequence Sequence >
< Step Step >
Monitor Camera
123 1234
Allegiant
Przeglądanie stron 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 47 48

Komentarze do niniejszej Instrukcji

Brak uwag