CCTV | Allegiant® Matrix Switcher Systems | Selection Guide | May 2009
www.boschsecurity.us 800.289.0096
Other accessory products may be applicable in your system
conguration. Please refer to the section on Allegiant
Accessories for complete details on accessory products.
Installation basics:
Install main bay in rack. If applicable, install monitor
expansion bay in rack, and connect supplied video ribbon
cables between the two bays. Insert the VIMs and VOMs
into the bay(s), then connect camera and monitor coax
cables to BNC connectors found on rear of unit(s). Connect
one or more keyboards for programming and control. If
applicable, connect external PC, external Alarm Interface
unit for alarms, external Signal Distribution unit for camera
control functions, and any applicable port expander device
to appropriate data connections on rear of unit.
System programming can then be accomplished using
either a system keyboard or via one of the optional external
Bosch PC based software packages (see accessory
section).
“From the Matrix Switch to every monitor and camera, I have
been more than pleased with the high quality standards of
every Bosch product we use.”
Daniel W. Eitnier
Director of Surveillance
Venetian Resort Hotel Casino
An external power supply will be required for each Alarm
Interface Unit when quantities are greater than 1. The
TC120PS power supply is used for 120VAC line sources,
and the TC220PS is used for 230VAC line sources.
If the system will include controllable PTZ equipped
cameras, add one LTC 8568/00 Signal Distribution Unit
for up to 32 separate control code outputs or one LTC
8768/00 Signal Distribution Unit for up to 64 separate
control code outputs. If required, LTC 8569/x0 or LTC
8571/x0 series Code Merger Units models are available
which provide an additional 32 or 64 outputs respectively
when cascaded to the Signal Distribution unit.
If the system will utilize more than 8 keyboards for a
single main bay only system, or more than 16 keyboards
if an LTC 8802/x0 Monitor Expansion bay is used, a
quantity of LTC 8714/x0 Keyboard Port Expanders will be
required and, if necessary, an LTC 8715/x0 Keyboard
Expander Expander unit. For each expanded keyboard, a
LTC 8557/x0 Remote Hookup kit will also be required.
Refer to the table below to determine the appropriate
quantity of Port Expander units:
Keyboard Expander Quantities
No LTC 8802/x0
Monitor Expansion bay
With LTC 8802/x0 Monitor
Expansion bay
System
LTC
8714/x0
LTC
8715/x0
System
LTC
8714/x0
LTC
8715/x0
Keyboards
Expander
Quantity
Expander
Quantity
Keyboards
Expander
Quantity
Expander
Quantity
1 to 8 0 0 1 to 8 0 0
9 to 16 1 0 9 to 16 0 0
17 to 24 2 1 17 to 24 1 0
25 to 32 3 1 25 to 32 2 1
Photograph courtesy of the Venetian Resort Hotel Casino.