Bosch VEN-650V05-2S3F Instrukcja Obsługi Strona 33

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 32
34 en | Operation EX65 Explosion-protected Camera
F.01U.412.061 | 1.0 | 2011.03 Instruction Manual Bosch Security Systems, Inc.
8.5.6 Test signal submenu
8.5.7 Camera ID submenu
Bilinx Comms. On, Off If Off, Bilinx communications is disabled.
Camera buttons Enable,
disable
Enable or disable the camera buttons from working.
Cable compensation Off, Default,
RG59, RG6,
Coax12
Cable compensation is used to avoid the need for
amplifiers in long distance coaxial connections up to
1000 m (3000 ft). For optimum results select the
coaxial cable type used or, if unknown, select default.
Compensation level 0,1,2 . . .+15 Sets the level of cable compensation
EXIT Returns to Install menu.
Item Selection Description
Item Selection Description
Show camera ID Off, On Select On to overlay the camera ID on the video test
signal.
Test pattern Color bars 100%,
Grayscale 11-step,
Sawtooth 2H,
Checker board,
Cross hatch,
UV plane
Select the desired test pattern to help installation
and fault-finding.
EXIT Returns to Install menu.
Item Selection Description
Camera ID Enter a 17-character camera name. Use Left/Right to
change position in the string; use up/down to select
character. Use Select to exit.
Display ID pos. Off, Top left,
Top right,
Bottom left,
Bottom right
Select the screen position of the camera ID.
Camera ID
border
On, Off Displays a grey border behind the camera ID to make it
easier to read.
MAC address Shows MAC address (factory set, cannot be changed).
Przeglądanie stron 32
1 2 ... 28 29 30 31 32 33 34 35 36 37 38 ... 46 47

Komentarze do niniejszej Instrukcji

Brak uwag