Bosch DIP-7082-8HD Instrukcja Instalacji

Przeglądaj online lub pobierz Instrukcja Instalacji dla Serwery Bosch DIP-7082-8HD. Bosch DIP-7082-8HD Installation manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - DIVAR IP 7000 2U

DIVAR IP 7000 2UDIP-7080-00N, DIP-7082-8HD en Installation Manual

Strona 2

ChassisThe chassis includes 8 hard drive bays and supports a 2U backplane, 3 fans and two powersupplies.BackplaneEach chassis comes with a 2U backplan

Strona 3 - Table of contents

Front view:152634 71 Power Failure 5 Power2 Overheat/Fan Fail 6 Reset3 NIC1/NIC2 7 Power on/off4 HDD Rear view:26715341 2x mains connection 100 –

Strona 4

– Reset: The reset button is used to reboot the system.– Power: The main power switch is used to apply or remove power from the powersupply to the se

Strona 5 - Safety precautions

– Green: Each Serial ATA drive carrier has a green LED. When illuminated, this green LED(on the front of the SATA drive carrier) indicates drive activ

Strona 6 - Electrical safety precautions

Chassis setup and maintenanceThis chapter covers the steps required to install components and perform maintenance on thechassis.!Caution!Review the wa

Strona 7 - Operating precautions

Installing hard drivesThis chapter describes the removing and installing of hard drives.Removing hard drive traysThe drives are mounted in drive carri

Strona 8 - FCC and ICES compliance

Installing a hard driveThe drives are mounted in drive carriers.To install a hard drive to the hard drive carrier:1.Remove the screws securing the du

Strona 9 - System overview

Notice!We recommend using the respective Bosch hard disk drives. The hard disk drives as one ofthe critical component are carefully selected by Bosch

Strona 10 - System interface

Replacing or installing a DVD-RWThe chassis model includes a pre-installed slim DVD-RW drive.1 DVD-RW 2 Front Port Panel To replace or install a DVD d

Strona 11 - Control panel buttons

1 DVD-RW 2 Front Port PanelTo replace or install the front port panel:1.Turn off and unplug the unit.2. Remove the chassis cover.3. Disconnect the pow

Strona 13

To install the air shroud:4 Place air shroud in the chassis. The air shroud fits behind the two fans closest to thepower supply. Note: If a 16 DIMM (1

Strona 14 - Chassis setup and maintenance

11 Release Tab!Warning!The fans might still be turning when you remove the fan assembly from the chassis. Keepfingers, screwdrivers, and other objects

Strona 15 - Installing hard drives

LED status:–Amber lighted LED: The power supply is off.– Green lighted LED: The power supply is operating.!Warning!Redundant power suppliesThis unit m

Strona 16 - Installing a hard drive

Replacing the power distributorRedundant server chassis that are 2U or greater require a power distributor. The powerdistributor provides failover and

Strona 17 - Installing a fixed hard drive

Rack installationThis chapter provides a quick setup checklist to get your chassis up and running. Followingthese steps in the order given should enab

Strona 18

– If the rack is provided with stabilizing devices, install the stabilizers before mounting orservicing the unit in the rack.–This unit should be moun

Strona 19 - Installing the air shroud

Rack mounting instructionsThis section provides information on installing the chassis into a rack unit. There are a varietyof rack units on the market

Strona 20 - Replacing the system fans

4. Separate the inner rail extension from the outer rail assembly.Installing the inner railsThe chassis includes a set of inner rails in two sections:

Strona 21 - Power supply

To install the outer rails to the rack:1.Secure the back end of the outer rail to the rack, using the screws provided.2. Press the button where the tw

Strona 22 - Replacing the power supply

Installing the chassis into a Telco rackTo install the chassis into a Telco type rack, use two L-shaped brackets on either side of thechassis (four in

Strona 23

Table of contents1Safety precautions 51.1 General safety precautions 51.2 Electrical safety precautions 61.3 ESD precautions 71.4 Operating precaution

Strona 24 - Rack installation

System setup - first stepsThe following installation directive provides information on Installation and Configuration.DIVAR IP systems are based on Wi

Strona 25 - Rack mounting considerations

8. After entering the password, a message is displayed that you must change the passwordbefore logging on the first time. To confirm, click OK.9.Chang

Strona 26 - Rack mounting instructions

– configuring external storage devices–all advanced configurations beyond a basic setup (maps or alarms, for example)For these tasks refer to the Bosc

Strona 27 - Installing the inner rails

Network settings pageYou configure the network settings of the operating system.As soon as you click Next button, the settings are activated.If you ha

Strona 28

Time settings pageYou configure the time settings of the operating system. 34 en | System setup - first steps DIVAR IP 7000 2U2013.09 | V2 | DOC Inst

Strona 29 - Turning on the system

Video settings pageThis page displays the devices and services that are included in the latest saved configuration.You can import a configuration. DI

Strona 30 - System setup - first steps

Device selection pageThis page displays all video devices that are not included in the latest saved configuration.Deselect the devices that should not

Strona 31 - Using Configuration Wizard

Device passwords pageThis page is used to authenticate password protected devices. This can either be done for allcameras at once (if passwords are id

Strona 32

Recording profile pageFor different profile assignments to different cameras you must execute Configuration Wizardmultiple times.Note:Before selecting

Strona 33

The default schedule is used for all recording profiles.The Day schedule is active from 8 a.m. until 6 p.m., Monday through Friday.The Night schedule

Strona 34 - Time settings page

4.3.4 Installing the chassis into the rack 284.3.5 Installing the chassis into a Telco rack 294.4 Turning on the system 295System setup - first steps

Strona 35 - Video settings page

Add storage pageThis page allows the addition of additional iSCSI storage devicesFor limitations, refer to the datasheet available in the online catal

Strona 36 - Device selection page

User accounts pageYou can add users and passwords. Use Configuration Client to add user groups and to changepermissions. DIVAR IP 7000 2U System setu

Strona 37

Finish configuration pageAfter clicking Save and activate the configuration is activated.After successful activation the Activate Configuration page i

Strona 38

Using Bosch VMS Operator ClientUse Bosch VMS Operator Client to verify the live, recording and playback functionality ofDIVAR IP.To verify live image

Strona 39

Recovering the unitSystem recovery optionsFollowing procedure describes how to restore the factory default image.To restore the unit to factory defaul

Strona 40

Basically, the RAID controller writes the raidconfiguration - information (COD = configuration-on-disk) in an only field on each disk managed by the c

Strona 41 - User accounts page

The data area can only be deleted with a "fast" or "full" initialization; as long as an initializationis omitted, the OS file syst

Strona 42

How to use the Event Viewer in the Controller Bios UtilityClick on an event in the main screen; choose "physical" or "virtual drive&quo

Strona 43

The VD event reports first a degraded state, then an offline state. The "first failed" disk wasthe rebuilding PD4. When PD6 failed, the rebu

Strona 44 - Recovering the unit

===========None seqNum: 0x0000188bTime: Mon Jul 19 13:52:41 2010 Code: 0x00000070Class: 1Locale: 0x02Event Description: Removed: PD 06(e0xfc/s6)Event

Strona 45

Safety precautionsObserve the safety precautions in this chapter.General safety precautionsFollow these rules to ensure general safety:–Keep the area

Strona 46

Event Data:===========Target Id: 1Useful commands: MegaCli -AdpEventLog -GetEvents -info -f info.txt -aALL(but a large text file) MegaCli -AdpEventLog

Strona 47

Select one of the two configurations and click Preview.All disks are seen, but configuration is marked as not importable; click Cancel and viewConfigu

Strona 48

Before clear foreign configuration, 2 disks were missing, two were foreign. After clear, theforeign disks now are shown as unconfigured.Use the event

Strona 49

Now in Logical View we see this disk marked as offline; click on the disk to get in PD menu.Click on "Make online" and "go".Now in

Strona 50

Foreign configuration disk appears in the Windows GUI after bootingThe RAID is degraded. Topology error is shown. Right-click Megaraid Controller in t

Strona 51

MegaCLI Commandline Utility[-Silent] [-AppLogFile filename] [-NoLog] [-page [N]][-] is optional.N - Number of lines per page. MegaCli -vMegaCli -help|

Strona 52

1=Disable Cache Bypass.MegaCli -AdpSetProp -LoadBalanceMode -val -aN|-a0,1,2|-aALLval - 0=Auto Load balance mode.1=Disable Load balance mode.MegaCli -

Strona 53

MegaCli -PDMakeGood -PhysDrv[E0:S0,E1:S1,...] | [-Force] -aN|-a0,1,2|-aALLMegaCli -PDMakeJBOD -PhysDrv[E0:S0,E1:S1,...] -aN|-a0,1,2|-aALLMegaCli -PDHS

Strona 54

[CachedBadBBU|NoCachedBadBBU][-strpszM][-szXXX[-szYYY ...]][-AfterLdX]|[FDE|CtrlBased] -aNMegaCli -CfgAllFreeDrv -rX [-SATAOnly] [-SpanCount XXX] [WT|

Strona 55 - MegaCLI Commandline Utility

MegaCli -PDCpyBk -Stop|-ShowProg|-ProgDsply -PhysDrv[E0:S0] -aN|-a0,1,2|-aALLMegaCli -PDInstantSecureErase -PhysDrv[E0:S0,E1:S1,...] | [-Force] -aN|-a

Strona 56

!Warning!Lithium battery:Batteries that have been inserted wrongly can cause an explosion. Always replace emptybatteries with batteries of the same ty

Strona 57

Additional documentation and client softwareDocumentation for Bosch Security System products can be found as follows:4 www.boschsecurity.com > sele

Strona 58

AppendicesThis chapter gives information for supporting and troubleshooting. MotherboardAll graphics shown in this chapter were based upon the latest

Strona 59

Motherboard component overviewFigure 8.2: Motherboard – component overviewX8SIL/X8SIL-F/X8SIL-V jumpersNumber Jumper Description Default38 JPUSB1 BP U

Strona 60

X8SIL/X8SIL-F/X8SIL-V headers/connectorsNumber Connector Description4,16 COM1/COM2 COM1/2 Serial connection headers33,32,27,23,7 Fans 1~5 System/CPU f

Strona 61 - Appendices

Motherboard featuresCPU Single Intel Xeon 3400 series processor in an LGA1156 socket.Memory Four (4) 240-pin, DDR3 SDRAM DIMM sockets with support for

Strona 62

Two (2) USB ports on the rear IO panelFour (4) USB header connectors for front accessOne (1) Type A internal connectorKeyboard/MousePS/2 Keyboard/Mous

Strona 63

Drivers and software for Intel 3400/3420 chipset utilitiesOther ROHS 6/6 (Full Compliance, Lead Free)Dimensions Micro ATX form factor, 9.6" x 9.6

Strona 64 - Motherboard features

better performance than comparable systems. The X8SIL/X8SIL-F/X8SIL-V also features a TCOtimer (to enable the system to recover from a software/hardwa

Strona 65

the system to keep the required circuitry "alive". In case the system malfunctions and youwant to turn off the power, just press and hold th

Strona 66 - Chipset overview

For the X8SIL/X8SIL-F/X8SIL-V motherboard, iSCSI is supported on LAN 1. This can beenabled through the BIOS: Advanced => PCI/PnP Configuration =>

Strona 67 - Power configuration settings

– Use only one hand when working with powered-on electrical equipment. This is to avoidmaking a complete circuit, which will cause electrical shock. U

Strona 70

Bosch Sicherheitssysteme GmbHRobert-Bosch-Ring 585630 GrasbrunnGermanywww.boschsecurity.com© Bosch Sicherheitssysteme GmbH, 2013

Strona 71

Note:Please handle used batteries carefully. Do not damage the battery in any way. A damagedbattery may release hazardous materials into the environme

Strona 72

System overviewDIVAR IP 7000 is an affordable, simple and reliable all-in-one recording, viewing andmanagement solution for network surveillance syste

Komentarze do niniejszej Instrukcji

Brak uwag