Bosch Rexroth Canada ı 16.10.2008 ı Revision 2.2
4.3 Parameter Description
Function
Parameter
No.
Description
Setting the
spread rates
1 to 9
Nine spread rates can be c
onfigured. The rate programmed
under Parameter 1 will be the rate under position 1 of the
conveyor dial in operation mode. Parameter 9 is position 9 of
the conveyor dial.
Setting the
spinner speed
11 to 19
Nine spinner speeds can be configured. The rate p
rogrammed
under Parameter 11 will be the rate under position 1 of the
spinner dial in operation mode. Parameter 19 is position 9 of
the spinner dial.
Selection of
Solid control
mode
20
Allows the selecti
on of one of five control modes:
“Manual”, “12V triggered”, “Ground speed triggered”,
“Open Loop” and “Closed loop”. See page 3 for a more in-
depth description of operation.
• Toggle the power on and off to accept the control mode
change.
Conveyor
Autonull
21
Used to automatically set the minimum and
m
ax
imum valve
setting on the conveyor. Available in closed loop mode.
Calibrating
solid material
22
Material calibration
s. See “calibration procedure” o
n page 1
4
.
Weight per
minute at max
speed
23
The result of the calibration process in LBS or Kg per minut
e
is shown here. This value represents the maximum material
dispensed per minute. Available in open loop mode.
Weight per
revolution of
conveyor
24
The result of the calibration process in LBS or Kg per
revolution is shown here. Available in closed loop mode.
Selection of
Liquic control
mode
25
Allows the selection of one of five control modes:
“Manual”, “12V triggered”, “Ground speed triggered”,
“Open Loop”, “Closed loop”, “Fixed
and “Anti-ice”. See
page 3 for a more in-depth description of operation.
• Toggle the power on and off to accept the control mode
change
Liquid auto
-
nulling
26
Used to automatically set the minimum and maximum valve
settings of the liquid pump. Available in closed-loop mode.
Liquid
calibration
27
Material calibrations. See
Calibration procedure“ on page 1
4
.
Pulses per
liquid volume
28
The result of the calibration process gallons or litres per
revolution is shown here. Available in closed-loop and anti-ice
mode.
Blast Alarm
-
seconds
33
This parameter set the time allowed
in Blast mode before an
alarm sounds. 0 = disabled 0-300 seconds, default = 15
seconds.