D720 Installation Guide
Page 2 © 2003 Bosch Security Systems74-06918-000-E
D720
Display
Note: Some points, such as fire points, may be programmed sothe sounder cannot be silenced until the point fault is
corrected. For additional programming information, refer to the appropriate Program Entry Guide (see Table 3 on
page 4).
Alarm Tones – When a fire point activates, the command center emits a fast, pulsating, high-pitched tone. When a burglary
point activates while the system is armed, the command center emits a steady burglary tone.
5.0 Display
The display annunciates four different types of status: armed, point, AC and battery power, and command mode (see
Figure 1).
PERIMETER
INTERIOR
INSTANT
12345678PWRCMD
1 2 3
4 5 6
7 8 9
ENT
7
COMMAND
ALL INSTANT DELAY
TEST WATCH
SPECIAL PARTIAL POLICE
A B C
Armed Status
Indicators
Point Status
Indicators
Power Status
Indicator
Command Mode
Indicator
Digital Keypad
Command Bar
A, B, C Function Keys
Sounder
Figure 1: The D720 Command Center
5.1 Armed Status Indicators
Armed Status Indicators show the armed condition of the area to which the command center has been assigned. (Command
centers are assigned to areas in the Cmd Cntr Assignment section of the panel program). Three different indicators show the
area armed status:
Perimeter – When this indicator is lit, the area perimeter points are armed. During exit delay time, this indicator flashes
slowly.
Interior When this indicator is lit, the areas interior points are armed. During exit delay time, this indicator flashes slowly.
Instant – When this indicator is lit, the area is armed without entry/exit delay time.
5.2 Point Status Indicators
The command center contains eight numbered indicator lights, which are used to annunciate the condition of the areas
protective points (see Figure 1).
Point Fault – While a point is faulted, its indicator lights steadily. When the point is restored to normal, the indicator goes
off.
Point Alarm Memory – A point alarm memory condition causes the indicator light to flash on and off rapidly. The
indicator continues to flash rapidly until the system is next armed or [COMMAND][4] is entered.
Bypassed Point – When a point is bypassed, the points indicator flashes “on and off slowly. The indicator continues to
flash slowly until the system is disarmed, or with some systems, the point may be unbypassed.
Note: Protective points may be programmed as invisible. When programmed invisible, the status of the point is not
displayed for alarm conditions.