D720 Installation Guide
D720
Page 3© 2003 Bosch Security Systems 74-06918-000-E
Setting the Command Center Address
5.3 Command Mode Indicator
When the [COMMAND] bar is pressed, the command mode indicator is lit approximately 15 seconds or until the
command is completed.
5.4 Power Indicator
The Power (PWR) indicator is on when AC power is present and the battery is good. The Power ([PWR]) indicator is off
when AC power is not present. The Power ([PWR]) indicator blinks slowly when battery power is low and AC is present.
The Power ([PWR]) indicator blinks quickly when battery power is missing and AC is present.
Indicator AC BATT
OFF NO YES*
ON YES GOOD
SLOW YES or NO LOW
FAST YES MISSING
*If AC is not present and the battery becomes depleted,
the command center will
g
ive no indication at all.
Table 1: Power Indicator Status
6.0 Setting the Command Center Address
Switches 1 to 4 on the D720 assign an address (1 to 8) to the command center (refer to Figure 2 below and Table 2 on page
4). The address determines the area to which the command center is assigned. Switch 5 allows you to enable or disable the
keystroke entry tone, and switch 6 allows you to enable or disable keypad backlighting. The Slide Switches can only be set
while power is removed from the command center. If the switch positions are reset while the command center is powered up,
the changes will have no effect on the subsequent performance of the command center.
123
4
56
789
0
COMMAND
ABCENT
123456
ON
OFF
DIP Switches
Serial Data
Wiring Connector
Wire Opening
Figure 2: Internal Features