Bosch 7000 Series Instrukcja Instalacji Strona 57

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 56
D9000/D7000 Series Operation & Installation Manual
Page 57
74-07692-000-C 4/97
System Wiring Diagrams, Issue A
P
P
P
P
S
D122 DUAL
BATTERY HARNESS
ARMING ST ATION
TO RJ31X FOR
PRIMARY
PHONE LINE
TO RJ31X FOR
SECONDARY
PHONE LINE
1
6
V
A
C
4
0
V
A
6
0
H
Z
T
R
A
N
S
F
O
R
M
E
R
AS
REQUIRED
D1255
UP TO EIGHT
SUPERVISED
D105 F EOL
DE VIC E
GND
AUX
OUT
IN
D928
D105 BL
EOL D EVICE
(FOR TYPICAL BURGLAR
ALARM APPLICAT IONS)
SUITABLE FO R V ALVE TAMPER
AND OTHER TY PES OF
EXTINGUISHING SYSTEM
SUPE RVIS ION.
TYPICAL INITIATING DEVICES ARE
DOOR CONTACTS NO/NC, FLOOR
MATS, MOT ION SENS ORS, GLAS S
BREAK DETECT ORS, ETC.
DATA
AUX
GND
D8129
OCTORELAY
D8125 POPEX 1
P
P
S
S
-+
-+
D125B
110342
or
5
LOOP
A
D129
6 7 5 8 9
1
2
3
4
10
11
12 13
D129 PROVIDES OPTIONAL
WATERFLOW ALARM RETARD
FEATURE. NOT SUITABLE FOR 2-
WIRE SMOKE DETE CT ORS. NOTE:
USE ZERO RET ARD EXCEPT FOR
WATERFLOW.
LOOP B
D192C
P
P
S
S
+
-
ECL DEVICE 15-03130-001
LISTED
AUDIBLE
SIGNALING
DEVICES
RATED AT 10.2
TO 13.8 VDC
(DO NOT USE
VIBRATING
TYPE HORNS)
AUX PWR
ALARM TRIG
COM
SUPV
IN
ALARM CKT
P
- - +
D126
BATTERY
12V 7Ah
D126
BATTERY
12V 7Ah
CONNECT UP
TO EIGHT
OCTORELAYS
IN
OUT
AUX
GND
D8125 POPEX 2
P S
P S
-
+
-
+
DATA
AUX
GND
D8129 OCTORELAY
OR D811 ARM STATUS RELAY
CONNECT UP
TO EIGHT
OCTORELAYS
P S
P S
P
P
J3
P S
P S
P
S
P
S
= POWER LIMITED
= SUPERVISED
D1640
D8132
BAT TERY
CHARGER
D126
BA TTERY
12V 7Ah
D126
BA TTERY
12V 7Ah
D8004 TRANSFORMER
ENCLOSURE.
REQUIRED FOR NFP A
APPLIC ATIONS .
OR D811 ARM STATUS RELAY
PARALLEL
PRINTER
S
S
S
S
+
P
D9210B ACCESS
CONTROL INTERFACE
5
9
10
1
4
2
Low B att e ry
LEDs Of f When Norma l
EAR TH GROUND
CO M MO N
CLASS 2 T RANSFORMER
16.5 VAC 40 VA 60 HZ
Part No. D1640
In tern a ll
y
Fused - Do Not Sho rt
Re
q
u ires Unswitched Outlet
Do Not Share Wit h Other E
q
u ipment
+ AU X POWER
BATTERY NEGATIVE ONLY
Maximum Char
g
in
g
Current 1.4 Amps.
PHONE MONITOR SELECT
Loop Start
Gr ound S tar t
TELCO
CORD
PHONE
LE D
ON WHEN
CO M MUNI CATIN G
OFF WHEN IDLE
WA RNING!
M u lti -Ba t te r
y
Installation Re
q
uires
Mo del No. D122 Dual Batter
y
Har ness
Improper Installation Ca n Be a Fi re Hazard .
Re
q
uires
Rela
y
#D1 36
IN J5
Ba tter
y
: Rep lace ever
y
3 to
5
y
ears with Model D1 26
,
12 V
7Amp Hr Le ad Acid Ba tter
y
ON -BOAR D POIN TS
1.0K Resistor
Re
q
uir ed at E n d of Li ne
VOL TAGE RA NGE S
Open 3. 7 - 5.0VDC
Norma l 2. 0 - 3.0VDC
Short 0. 0 - 1.3VDC
PERIPHER AL DEVICE W IRING
ZONEX OUT 1
Z ONEX IN 1
ZONEX OUT 2
Z ONEX IN 2
ZONEX POWER +
ZON EX CO MMON
Operation M onitor
P ulses Wh en Norma l
Flickers Wh en Rin
g
in
g
PROG
CONN
RED
YELLOW
GREEN
BLACK
17 -05823-002
32
POW ER +
DATA BU S A
COMMO N
RED
GRO UND
STAR T
YEL
RED
Re set P in
D isable All Ex ce pt Batter
y
Char
g
in
g
An d Pro
g
rammin
g
GRN
STE ADY OR
PU LSE
+
Ch a r
g
in
g
Status
N.F.P.A.
St yle 3.5
Si
g
nalin
g
Line
Circuits
POWER SUPPL Y REQUIREMENT S
The P owe r Suppl
y
Provide s a Maxi mum of 1 .4 Amps For The C ontrol and
All Acce sso r
y
Devices For S
y
stem Loa din
g
. S ee Operat ion- Inst allation M anual
#74 -0762 9-000.
All Exter nal Conne ctions E xcept Te rminal
(
Ba tter
y
Positive
)
Are Inhe rentl
y
Pow er L imited.
Re
q
uire men ts Fo r B atter
y
Stand b
y
Time Ma
y
Reduce Allowable O utput.
C AUTIO N: See M anual Fo r P ower Re
q
uirem ents Relatin
g
to Te rm inals
R eference M anual #74-0 6144-00 0 For S
y
s te m W iri n
g
Dia
g
ram Issue A
,
R eference M anual #73-0 6143-00 0 For Com patible Smok e De tectors
12
15 18 21
13
11
14 16 17 19 20 22
5
6 7
PROGR AMM ABLE
ALARM OUTPUTS
Terminals
&
Re qui res
Optional
D136 Relay
in J1 & J9
7 8
Point 1 Point 2 Point 3 Point 4 Point 5 Po int 6 Point 7 Point 8
D ATA BUS B
29
31
30
24
23
28
27
26
25
BATT ERY POS ITIV E ONL Y
+ ALTERNATE
SW I T CH ED
AUX POWER
+
3
6
7
8
This E
q
uipme nt should be installe d in accordance with the NFP A 70
(
Natio nal Electr ic Code
)
and applicable 71 Centr al S tation
,
72 Chapt er 6 Local
,
72 Chapter 8 Rem ote S tation
,
74 H ousehold F ire
(
National Fir e p rotection Associatio n
,
Batter
y
marc h Pa rk
,
Quinc
y
,
MA 02269
)
.
Prin ted inform ation des cribin
g
proper installation
,
ope ration
,
tes tin
g
,
maintenance
,
e vacuation
plan nin
g
and repair service is to b e provided with this e
q
uipment.
D9412 Control/Communicator is UL Listed for Central Sta tion
,
Local
,
Remote S tation and Household
F ire Alarm
,
and Central Station
,
Local
,
Police Station C onnect and Household Bur
g
lar Alarm.
D9131A PARALLEL
PRINTER
INTERFACE
UP TO E IGHT
SUPERVISED
S
S
S
S
33 K EOL
RESIS TOR
D9412
Di
g
ital A larm
,
Com mun ic ato r Tra nsm itte r
Up to 119 D 912 7 U/T PO PITS , and
up to 6 4 D8127 U/T POP ITS
Up to 119 D9127 U/T PO PITS, and
up to 64 D8127 U/T POPITS
U p to 14 D8128C Octo PO PITs
U p to 14 D8128C OctoP O PITs
SS
S
S
S
S
D9412 Control/Communicator
Przeglądanie stron 56
1 2 ... 52 53 54 55 56 57 58 59 60 61 62 ... 66 67

Komentarze do niniejszej Instrukcji

Brak uwag