CC484/CC486/CC488 | Operators Manual | 3. Codepad Indicators EN | 6
Bosch Security Systems | 6/04 | 4998152445B
3.1 Zone Indicators
1 2 3 ….
The zone indicators (1 to 8) display
the status of the zones. Table 2 lists the
various circumstances that the
indicators display (such as Zone
Sealed, Zone Unsealed, and so on).
Table 2: Zone Indicators
Indicator Definition
On Zone is unsealed.
Off Zone is sealed.
Flashing Fast
(0.25 seconds on/
0.25 seconds off)
Zone is in alarm condition.
Flashing Slow
(1 second on/
1 second off)
Zone is manually isolated or
selected to be isolated.
3.2 AWAY Indicator
The AWAY indicator displays that the
system is armed in AWAY Mode. The
AWAY indicator flashes in unison with
the STAY indicator when
programming various options
throughout the Operators Manual.
See Section 3.10.2 Arming in AWAY Mode
for information on the different
methods of arming the system in
AWAY Mode.
Table 3: AWAY Indicator
Indicator Definition
On System is armed in AWAY Mode.
Off System is not armed in AWAY Mode.
3.3 STAY Indicator
The STAY indicator displays that the
system is armed in STAY Mode 1 or
STAY Mode 2. The STAY indicator also
flashes in unison with the AWAY
indicator when programming various
options throughout the Operators Manual.
See Section 3.10.3 Arming in STAY Mode 1
for different methods of arming in STAY
Mode 1. See Section 3.10.4 Arming in
STAY Mode 2 for the method of arming in
STAY Mode 2.
Table 4: STAY Indicator
Indicator Definition
On System is armed in STAY Mode 1
or STAY Mode 2.
Off System is not armed in STAY
Mode 1 or STAY Mode 2.
Flashing
twice a
second
Zone isolating mode or setting
STAY Mode 2 zones.
Flashing once
every
3 seconds
Day alarm status – day alarm
turned on.
3.4 System Disarmed
This indicator displays with the
indicator when the system is disarmed.
3.5 MAINS Indicator
The MAINS indicator displays that the
system’s AC mains supply is normal or
failed.
Table 5: MAINS Indicator
Indicator Definition
On AC mains power normal.
Flashing AC mains supply has failed.
3.6 Off Indicator/Zone Sealed
The indicator displays when the
system is in the disarmed state and
flashes when a zone becomes unsealed
during the disarmed state. The
indicator stops flashing when all zones
are sealed.
3.7 On Indicator/Zone In Alarm
The
indicator displays when the
system is armed in AWAY Mode and
flashes when an alarm occurs. The
indicator resets once a valid user code
is entered.
Komentarze do niniejszej Instrukcji