Bosch D9112B Podręcznik Użytkownika

Przeglądaj online lub pobierz Podręcznik Użytkownika dla Systemy kontroli dostępu bezpieczeństwa Bosch D9112B. Bosch D9112B User`s guide Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - User’s Guide

Security SystemUser’s Guide

Strona 2

If there are bypassed points, AREA 1 ## BYPAS (## =total number of bypassed points) is displayed, followedby the point text descriptions of the bypas

Strona 3 - Table of Contents

The group with the highest priority scrolls first in the commandcenter’s display. Descriptions of the tones and displays for eachgroup and instruction

Strona 4 - AREAXISOFF

Fire AlarmsFire alarms are the highest priority events. When a fire pointactivates, your command center emits a pulsating high-pitchedfire tone. Evacu

Strona 5 - Introduction

See VIEW MEMORY? (COMMAND 40) for more information.To clear the event memory and remove the ALARM SILENCEDmessage from the display, enter a valid pas

Strona 6 - Command Center Function Keys

Fire Trouble EventsWhen a fire trouble occurs, your command center emits threewarble tones, then a pause (repeatedly).The system displays the number o

Strona 7 - Security System Basics

Non-Fire Trouble EventsWhen a trouble event such as an AC failure occurs, yourcommand center may be programmed to emit three warble tones,then a pause

Strona 8 - 24-Hour Points

Entry Delay Tone and DisplayWhen you enter an armed system through a point programmedfor entry delay, the command center emits a repeating tweedletone

Strona 9 - Your Custom Display

Keystroke Checking TonesValid EntryIf you press an appropriate key for the function or entry youdesire, the command center sounds a muted beep tone, i

Strona 10

System Commands & FunctionsBelow is a summary of the commands covered in this guide. Some of these functions may not be available in your system.

Strona 11 - Warning Displays and Tones

Turning the System On (Arming)Your security system can be turned on (armed) in many differentways, depending on the arming command used. ArmingCommand

Strona 13 - Burglary Alarms

Turning the System Off (Disarming)Your security system is turned off by entering your personalpasscode. When the system is turned on, you must enter t

Strona 14 - Fire Trouble Events

Turning the System On (Arming) WithDoors or Windows OpenIf a protected door or window is open, you may have the optionof “force arming” with that poin

Strona 15 - Non-Fire Trouble Events

NOT AUTHORIZEDThe authority level for your passcode does not give youthe authority to force arm.5. Press ENT with FORCE ARM displayed to arm yoursyst

Strona 16 - Exit Delay Tone and Display

MASTER ARM ? Turn the Entire System On With DelaysDescriptionUse this function to turn on the entire system, both perimeterand interior. When you tur

Strona 18

Using Master Arm Inst:1. The display shows idle disarmed text.2. Press the COMMAND bar. The display shows SYSTEMCOMMAND.3. Press the 1 key. Now press

Strona 20

PERIMETR INST ? Turn On the Perimeter With No DelaysDescriptionUse this function to turn on only the perimeter of your building,leaving the interior

Strona 21 - Duress Passcode

PERIMETR INST ? continued5. To disarm your security system, enter your personalpasscode and press ENT.

Strona 22

Using Perimetr Delay:1. Interior points are not armed with this command andmay remain faulted while arming with COMMAND 3.2. Press the COMMAND bar. Th

Strona 23 - MASTER ARM ?

Page CodeTable of ContentsIntroductionCommand Center Function KeysSecurity System BasicsYour Custom DisplayView Faulted or Bypassed PointsWarning

Strona 25 - MASTER ARM INST ?

Silence the Trouble Sounder & ClearTrouble Display DescriptionUse COMMAND 4 to silence the trouble sounder during systemevents. This command also

Strona 27 - PERIMETR INST ?

VIEW MEMORY ? View Event MemoryDescriptionYour system stores events that occurred since the last timememory was cleared. Use COMMAND 40 to view Event

Strona 29 - Description

WALK TEST ? Walk TestDescriptionUse this function to test command centers, detection devices,and sounders (both interior and exterior) to be certain

Strona 30

WALK TEST ? continued4. The burglary bell sounds for 2 seconds. When the displaypanel shows ## PTS TO TEST you can begin. Test eachpoint by first ope

Strona 31 - Trouble Display

3. Press the 4 key followed by the 7 key.Note: If you prefer, you may use the Command Menu in placeof steps 2 and 3 to initiate this function. Press t

Strona 33 - VIEW MEMORY ?

WATCH MODE ? Watch ModeDescriptionWith your security system disarmed, you can use watch mode tomonitor some points. Each time some points are faulted

Strona 34

Siren/Speaker1234567890COMMANDESCPREVNEXTENTALL INSTANT DELAYRESET WATCHSPECIAL PARTIAL POLICEBYPASSMENU YESAREAXISOFFAlphanumeric DisplayDigital Keyp

Strona 35 - WALK TEST ?

Exiting Watch Mode continued2. Press the COMMAND bar. The display shows SYSTEMCOMMAND.3. Press the 6 key.Note: If you prefer, you may use the Command

Strona 36 - WALK TEST ? continued

PERIMETR PART ? Partially Turn On the PerimeterDescriptionThis function is used to turn on the perimeter of your buildingwhile selected portions of t

Strona 37 - RESET SENSORS ?

PERIMETR PART ? continued5. When performing a COMMAND 8 and no points arefaulted or if the points return to normal before the exitdelay time expires,

Strona 38

Using COMMAND 7:1. Press the COMMAND bar. The display shows SYSTEMCOMMAND.2. Press the 7 key. Your COMMAND 7 special alert has beenprogrammed to:___ n

Strona 39 - WATCH MODE ?

Using COMMAND 9:1. Press the COMMAND bar. The display shows SYSTEMCOMMAND.2. Press the 9 key. Your COMMAND 9 special alert has beenprogrammed to:___ n

Strona 40 - Exiting Watch Mode continued

Security System LimitationsNot even the most advanced security system can guaranteeprotection against burglary, fire, or environmental threats. Allsec

Strona 41 - PERIMETR PART ?

Fire Safety and EvacuationResidential fire is a leading cause of accidental death. Most firerelated deaths occur at night when occupants suffocate in

Strona 42 - PERIMETR PART ? continued

Fire Safety and Evacuation continuedPlan both primary and alternate escape routes. Since stairwellsand hallways may be blocked during a fire, exiting

Strona 43 - Special Alerts and

NO AUTHORITYThe system does not recognize the passcode entered.NOT AUTHORIZEDThe passcode entered does not have the authority to Force Arm.PERIMETR

Strona 44 - Using COMMAND 9:

System Trouble DisplaysIf you see any of the system trouble displays shown below, contactyour security company to determine whether repairs are needed

Strona 45 - Security System Limitations

IntroductionYour security system helps to secure life, property, andinvestments against fire, theft, and bodily harm. The commandcenter is an advanced

Strona 46 - Fire Safety and Evacuation

SERVC PH LINE #1 (or 2)Indicates telephone line trouble. Call your phone company fromanother phone to report telephone trouble. This message maynot

Strona 47

Security System GlossaryArea - A group of detection devices connected to your securitysystem.Arm - To turn your controlled points (burglar detectionde

Strona 48 - Standard Displays

Force Arm - To turn on (arm) the security system even thoughone or more points are faulted. Force arming bypassesthe faulted points.Idle Text - The se

Strona 49 - System Trouble Displays

YOUR ALARM COMPANY IS CALL BEFORE TEST___________________Maintenance and ServiceThis security system requires very little maintenance, however,you

Strona 52

71-06141-000-C 02/03 D9112B

Strona 53 - Maintenance and Service

Command Center Function KeysYour command center has five function keys. These keys are usedto control your system.COMMANDUse the COMMAND bar in combin

Strona 54

Security System BasicsWhat is a Point?A “point” is a detection device, or group of devices connected toyour security system. Points display individual

Strona 55

24-Hour Points24-hour points are always on, even when the burglary system isdisarmed (turned off). There are two types of 24-hour points,fire points a

Strona 56 - 71-06141-000-C 02/03 D9112B

Your Custom Display“At an idle state” means that the system is not currently performing a function entered by a user. There are three idle states thes

Komentarze do niniejszej Instrukcji

Brak uwag