Bosch DS7400XiV4-EXP Instrukcja Użytkownika Strona 3

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 10
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 2
DS7400XiV4-EXP
DS7400XiV4-EXP Release Notes
4998154793B Page 3 © 2005 Bosch Security Systems
2.1.5 Network Communication Module 1 and
Module 2 Ack and Message Type
Configuration
Select if an acknowledgment from the receiver is
required for each alternate communication route. Also
select if anti-replay is required for each alternate
communication route.
Anti-replay is a strategy designed against replay
attacks. A replay attack occurs when a hacker records
a message sent over the network by Device A. The
hacker replays this message at a later time while
pretending to be Device A. This feature prevents
substituting a control panel and network interface
module (NIM) for delivering events over a network.
Addresses: 3031 (Module 1) and 3032 (Module 2)
Data Digit:
Data Digit 1: ____ (refer to Table 5;
default = 1)
Data Digit 2: ____ (refer to Table 6;
default = 0)
Selections: 0 or 1 for Data Digit 1; 0 to 3 for
Data Digit 2
Table 5: Ack Usage
Data Digit 1 Select Options Value
Do not use Central Station ack 0
Use Central Station acks
1
Table 6: Network Communication Routing
Data Digit 2 Select Options 0 1 2 3
Anti-replay off
Anti-replay on
Use Cobox™ header
Do not use Cobox™ header
2.1.6 Network Communication Module 1 Central
Station IP Address
Set the IP address of the Central Station receiver used
by Network Communication Module 1.
Each section of the IP address is stored in Address
3033, in HEX format. After entering all four sections,
press [#] to accept the values. For example, to
program the IP address 172.16.17.11, enter AC 10 11
0B [#]. Table 4 on page 2 shows the keys you must
press to generate HEX characters A through F. Table
19 on page 8 shows the HEX-to-decimal conversion
values.
Addresses: 3033
Default: 00 00 00 00
Selections: 0 to 9, *0 to *5 (hexadecimal values
that display as A through F at the keypads).
2.1.7 Network Communication Module 2 Central
Station IP Address
Set the IP address of the Central Station receiver used
by Network Communication Module 2.
Refer to Section 2.1.6 Network Communication Module 1
Central Station IP Address for more information.
Address: 3037
Default: 00 00 00 00
Selections: 0 to 9, *0 to *5 (hexadecimal values
that display as A through F at the keypads).
2.1.8 Programming Modules 1 and 2 for Network
Communication
Enable or disable the network communication
module.
Addresses: 4019 (Module 1); 3041 (Module 2)
Data Digit:
Data Digit 1: ____ (refer to Table 7;
default = 0)
Data Digit 2: Must = 0
Selections: 0 or 1 for Data Digit 1
Table 7: Network Communication Module 1 and 2
Configuration
Select Option Value
Module disabled
0
Module enabled 1
Przeglądanie stron 2
1 2 3 4 5 6 7 8 9 10

Komentarze do niniejszej Instrukcji

Brak uwag