Table 25: Transactions
Transaction Description Priority
Manual
Unlock
An operator has manually unlocked a door (see above.)
[1342] 02/12/93 16:14 DOOR NAME MASTER KEY Manual Unlock
No Access:
Holiday
A key has been presented, but a holiday period has been assigned to this keyholder’s time
profile.
[1444] 02/12/93 16:02 DOOR NAME KEYHOLDER No Access: Holiday
high
No Access:
Level
A key has been presented, but the access level assigned to the access code does not
include this door.
[1451] 02/12/93 16:03 DOOR NAME KEYHOLDER No Access: Level
high
No Access:
Locked Out
A key has been presented, but it is not been assigned any access code.
[1217] 02/12/93 15:02 DOOR NAME KEYHOLDER No Access: Locked Out
high
No Access:
Time
A key has been presented, but is not allowed through this door at this time.
[1456] 02/12/93 17:04 DOOR NAME KEYHOLDER No Access: Time
high
No Access:
Unknown ID
A key has been presented, but its passcode is unknown to the door controller.
[1362] 02/12/93 16:19 DOOR NAME ???? No Access: Unknown ID
high
No Entry:
Passback
A key has been presented, but will not be allowed through this door until it has left the pass-
back area.
[1466] 02/12/93 17:06 DOOR NAME KEYHOLDER No Entry: Pass Back
high
No Exit:
Passback
A key has been presented, but will not be allowed through this door until it has entered the
pass-back area.
[1475] 02/12/93 17:08 DOOR NAME KEYHOLDER No Exit: Passback
high
Override
Alarm
An override alarm input has opened all the doors attached to the door controller.
[1363] 02/12/93 16:20 DOOR CTRLR 1 Override Alarm
high
Override
Alarm Reset
The override input has been cleared, all the doors will close again.
[1364] 02/12/93 16:20 DOOR CTRLR 1 Override Alarm Reset
high
PIN Reader
Duress
Alarm
A PIN duress code has been entered on a K2001-P(PIN +1) and the door has opened.
[1319] 02/12/93 16:03 DOOR NAME KEYHOLDER PIN Reader Duress Alarm
high
Power Off The door controller has had its power removed, or the Reset button has been pressed.
[1222] 02/12/93 15:11 DOOR CTRLR 1 Power Off
high
Power On The door controller has been powered up, or the Reset button has been released.
[1223] 02/12/93 15:11 DOOR CTRLR 1 Power On
high
Repeated
Key Use
The same key has been presented continuously to a reader for 5 lock operations and the
door has closed.
[1252] 02/12/93 15:20 DOOR NAME KEYHOLDER Repeated Token Use
Request for
Entry
A special lock mode option can be used to allow a Request for Entry transaction. This may
be used when a button is used from inside an area to allow a person access.
[1481] 02/12/93 17:09 DOOR NAME Request for Entry
Request to
Exit
The Request to Exit switch has been used to open a door.
[1240] 02/12/93 15:19 DOOR NAME Request to Exit
high
RTE Button
Held Down
A Request to Exit button has been continuously operated 5 times and the door has closed
[1246] 02/12/93 15:20 DOOR NAME RTE Button Held Down
high