2 | CC100 Solution 16plus Control Panel
Chime Mode
Chime mode allows monitoring a zone or group of zones by
sounding the code pad buzzer or activating a programmable
output. This feature is ideal to monitor business entry doors
for customer entry during business hours.
Separate Tamper Inputs
Both the Solution 16plus Control Panel and all panel
modules feature a separate tamper input making remote
locating devices in a secure enclosure easy.
Walk test
Enables a user to test all zones within an area at the same
time. When the walk test feature is activated, the code pad
will display a list of areas available to walk test. Once the
area to test is selected all zones within the area will be
displayed. The user then walks the area and zones
successfully tested will be removed from display leaving
only those that failed to be activated on the code pad
screen.
Partitioning up to 4 Areas
The control panel supports up to 4 separate areas with no
restriction on the number of individual zones that can
belong in an area. You can assign all zones to a single area,
or you can assign each zone to a combination of different
areas. You can arm and disarm the control panel by area,
alternatively, you can arm and disarm several areas at the
same time.
Multiple areas can be linked to a shared area which is
automatically controlled (hallway or lobby). Area arming
may be conditional on other areas (master or associate).
Programmable Outputs
The Solution 16plus Control panel supports 4 on board
outputs and is expandable to 16 outputs in total. All outputs
are protected and will shut down individually under an
overload condition. Outputs conditions are displayed on
the code pad and may be reported externally if required.
Outputs may be triggered via an event and or manually, and
may be programmed for polarity, pulsing or one shot.
Proximity Control
Proximity technology from Bosch provides an affordable
and effective solution with up to 8 proximity code pads
supported on the control panel. Use of proximity code pads
reduces false alarms caused by user error.
Schedules
Up to 8 schedules may be implemented. Each schedule has
a start and stop time as well as day of the week and
holidays. Schedules may be used to automatically arm /
disarm the system at specific times or control outputs. They
may also control the ability for users to gain access at
different times of the day / week.
48 Users with flexible credentials and devices
Up to 48 individual users may be included in the system.
Each user can be given a unique PIN code, RF key fob and
Proximity token if required. The solution 16plus supports
variable length PIN codes up to 8 digits.
Variable PIN configuration
Users can be given free choice of PIN length or alternately
an exact PIN length requirement may be enforced for higher
security applications. PIN codes can be set to expire at a
pre-programmed time per user.
Flexible Communications Options
CID, SIA, DOMESTIC and SMS Text Reporting formats are
all standard out of the box and the dual reporting feature
allows you to select which reports are sent to which route
and in what format. Open / Close reporting can be selected
individually for each user and area on the panel allowing the
owner to monitor cleaner access, children returning home
from school or access to a particular restricted area all via
their mobile phone.
Delay Trouble Beeps
Setting this option will prevent any system trouble events
from sounding the code pad speaker between the hours of
10pm until 7am. During this time, any new trouble event will
be shown in the code pad display. If trouble events are still
in effect after 7am the code pad will begin to sound the
trouble alert to notify the user. This function is ideal for all
residential applications.
Event Log
The control panel stores up to 256 events from all areas. All
events are recorded in the log regardless of the reporting
setting. The event log may be viewed via the code pad, serial
printer or via a direct or remote connection from the
Solution Link programming software.
Certifications and Approvals
C-tick Supplier Code: N12138
New Zealand Telepermit: PTC 211 / 06 / 009
Installation/Configuration Notes
Code pads
Any combination of CP100W, CP101W, CP110B or CP111B
may be installed for up to 8 code pads in total.
Input Expansion
Wired or wireless zones may be configured in any quantity
per area up to 16 zones. Input zone expansion options are:
Using CM104 zone expanders
Komentarze do niniejszej Instrukcji