Bosch VMD01 M50 PAL Instrukcje Operacyjne Strona 17

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 122
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 16
– 17 – A1 February 03/Trb
Operating instructions, continued English
Access to alarm image memory:
Alarm images can be viewed before or after acknowledgement. To switch from
live images to alarm images, briefly press the key/rotary switch.
No alarm images present =
.
If alarm images are present, a display “0“ appears in the monitor picture, i.e. the
alarm occurred at this point in time.
Rotate the key/rotary switch to the:
left, for pre-alarm images right, for post-alarm images+”.
The object causing the alarm is outlined in red in the alarm image and in the
post-alarm image. The first detection of the object is outlined in yellow.
Movement of the object is outlined with a green line between the yellow and red
lines. See also chapter 3.1 (Overlaid lines for color and B/W signals). If an
image is displayed for longer than 5 seconds, the lines will disappear. Upon
switching further to pre or post-alarm images, these will first be displayed with
masks. The alarm mode is exited by briefly pressing again. There is a switch to
the live image if no operation in the alarm memory is carried out within
60 seconds.
Przeglądanie stron 16
1 2 ... 12 13 14 15 16 17 18 19 20 21 22 ... 121 122

Komentarze do niniejszej Instrukcji

Brak uwag