3. Guidelines for installation and electrical connections
KDV2/Montage.fh3
hexagon socket
with SW5
Note conductive connections
on backwall of control cabinet
and
mounting frame!
Cap screw / 4x
M4x18Z4-1 DIN912 (1)
Those parts labelled with (1) are a part
of blower assembly 109-0574-4819-XX.
Those parts labelled with (2) are in
of accessories kit M1 - 109-0575-4851-XX.
Blower for forced cooling
109-0575-4832-XX (1)
Only to be used in units with W1 cooling modes.
See description of KDV.
Cap screw / 2x
M4x14Z4 DIN912 (1)
Backwall of cabinet
Housing and control cabinet design
see drawing 109-0574-3004-XX
Panel cut-out for additional blowers
M4 thread
Mounting frame for blower
109-0575-4833-XX (1)
Finger guard
109-0575-3236-XX (1)
Mounting frame for K-module
109-0575-4831-XX (2)
Bleeder safety hood
109-0574-4820-XX
must always be mounted to
protect personnel and unit!
M8 thread
Panel for additional K-modules
Cap screw / 4x
M4x16 DIN912 (2)
(2) M4/4x contact disc
185
69
Clearance to flammable
materials or parts which can
be affected by heat:
at least 300 mm!
Threephase
KDV
supply module
Figure 3.13: Mounting the KDV 2.3 into the control cabinet