• DOK-POWER*-KDV*2.3****-ANW1-EN-E1,44 • 06.97
5. Interface descriptions
This makes it possible for the NC control unit to brake the drives to a standstill
with either a mains or phase failure. The power regenerated during braking
must be greater than the power consumed.
The Bb1 contact always switches the power supply off with a drive fault.
The superordinate control must guarantee that the drives are braked
with a closed NC bridge because the command-to-zero is dropped.
The superordinate control monitors the UD contact and brings the
drives to a standstill once the contact is open.
There will otherwise be an uncontrolled coasting of the drives if the
power supply system fails.
Do not use an NC bridge in digital drives with SERCOS interface. The
programmable error reaction of digital drives means a controlled
braking is possible without the bridge. The bridge prevents the
signal to the drive indicating there is a fault in the power supply.
Überw_Prinz.fh3
auxiliary voltage fails
bleeder and temperature
monitoring
error message from all drives
fault current monitoring
voltage in D.C. bus
less than / equal to 50V
voltage in D.C. bus
greater than / equal to 200V
mains phases functional
NH transistor output
switches to OVL
with fault
BVW opens
with fault
Bb1 contact
opens with fault
&
R
S
&
1
1
&
X 1/1
X 1/2
ϑ ≥ 80% ϑ
max
ϑ < ϑ
max
NCB
Signal to
drive units
operating
status + 15V
UD contact,
open with fault
Figure 5.3: Diagram of interfaces for monitoring and diagnostics systems