I-Frame Distance
This parameter allows you to set the intervals in which the I-Frames are coded. Click
Automatic, to insert I-Frames as necessary. An entry of 1 indicates that I-Frames are
continuously generated. An entry of 2 indicates that only every second image is an I-Frame,
and 3 only every third image etc. The I-Frames in between are coded as P-Frames.
Frame Quality Level
Here you can set a value between 0 and 100 for both the I-Frames and the P-Frames. The
lowest value results in the highest quality and the lowest frame refresh rate. The highest value
results in the highest frame refresh rate and the lowest image quality.
The lower the available transmission bandwidth, the higher adjust the quality level to maintain
high quality of the video.
Note:
You adjust the video quality dependent on the motion and level of detail in the video. If you
check the Automatic check boxes, the optimum relationship between motion and image
definition is automatically adjusted.
VIP X1600 XFM4 Settings
Allows you to configure the following H.264 settings for the VIP X 1600 XFM4 encoder module.
H.264 deblocking filter: Select to improve visual quality and prediction performance by
smoothing the sharp edges.
CABAC: Select to activate high efficient compression. Uses a large amount of processing
power.
Options dialog box
Main window > Settings menu > Options... command
Language
Allows you to configure the language of your Configuration Client. If you select Default system
language the language of your Windows installation is used.
Scan Options
Allows you to configure the scan process. Subnet allows that scanning is only active in the
current subnet. Cross subnet allows for scanning beyond a router in other subnets. If the scan
process does not find devices with one of these options, try the other one.
Analog Monitor Group (AMG) Settings
Allows you to configure that the users can control all analog monitor groups with each
Bosch VMS client computer. It is then not required to configure this computer as a
workstation in the Device Tree.
Logbook Configuration
Allows you to configure the connection string for the Logbook database. Change this string
only when you want to configure a remote SQL server for the Logbook and only when you are
familiar with SQL server technology.
Automatic Device Configuration
Enables that configurations of encoders and decoders are automatically aligned with the
Bosch VMS configuration settings. You can check the configuration settings of a device on its
property pages in the Device Tree.
Remote Access Settings dialog box
Main window > Settings menu > Remote Access Settings... command
Allows you to configure the port mapping for remote access.
You add one or more port ranges. Bosch VMS automatically assigns each private IP address of
a configured device to a different public port number of one these ranges.
22.9
22.10
140 en | Global Configuration Client windows Bosch Video Management System
2013.07 | V1 | Configuration Client Configuration Manual Bosch Sicherheitssysteme GmbH
Przeglądanie stron 139
1 2 ... 135 136 137 138 139 140 141 142 143 144 145 ... 259 260

Komentarze do niniejszej Instrukcji

Brak uwag