SNMP page
Main window >
Devices > Expand > Expand >
1. SNMP host address 2. SNMP host address
VRM supports the SNMP V2 (Simple Network Management Protocol) for managing and
monitoring network components, and can send SNMP messages (traps) to IP addresses. The
unit supports SNMP MIB II in the unified code. If you wish to send SNMP traps, enter the IP
addresses of one or two required target units here.
Some events are sent as SNMP traps only. Refer to the MIB file for descriptions.
Advanced page
Main window > Devices > Expand > Expand >
Activate the different logs for VRM Server and Configuration Manager, and specify the
retention time for log files in days. We recommend that you configure a logging retention time
not less than the longest minimum retention time of the cameras.
The log files for VRM Server are stored on the computer on which VRM Server has been
started, and can be viewed or downloaded with VRM Monitor.
The log files for Configuration Manager are stored locally in the following directory:
C:\Documents and Settings\<User>\My Documents\Bosch\Video Recording Manager\Log
Complete memory dump file
Only activate this option if necessary, for example if the Technical Customer Service team
requests a complete summary of the main memory.
Telnet support
Activate this option if access with the Telnet protocol is to be supported. Only activate if
necessary.
Caution!
Extensive logging requires considerable CPU power and HDD capacity.
Do not use extensive logging in continuous operation.
Pool page
Main window > Devices > Expand > Expand >
Allows you to configure recording settings valid for all devices that are collected in this
storage pool.
Recording preferences mode
Failover
Recordings are saved only to primary target. If it is not possible to save to this target, the
recording will be saved to the target entered under secondary target.
A failure situation is reached if the primary target does not provide storage blocks due to
whatever reason: system down, network error, no capacity left.
You can leave the second list empty. In this case no failover is possible but the number of
required iSCSI sessions is reduced and no disk space on secondary target is allocated.
This reduces system overhead and extends the system retention time.
Automatic
23.26.1
23.26.2
23.27