5.12 Connecting Analog Input Devices
The AMC2 4W has eight analog inputs, for example, for poten-
tial free lock mechanisms or to detect if a lock is closed or
open. The inputs will be connected to the 2-pin pluggable
screw connectors: S3, S4, S8, S9, S15, S16, S20, and S21.
Fig. 5.22 Location of the analog input connectors
The AMC2 4W can also detect the wiring conditions ‘short cir-
cuit’ and ‘broken’ and initiate an alarm if the appropriate
devices are connected.