D9412GV2/D7412GV2
D9412GV2/D7412GV2 Release Notes for Version 7.05
© 2007 Bosch Security Systems, Inc. Page 7 F01U003637-02
Remote Arm/ Disarm Output
Prompt:
Remote Warning
When enabled, this feature uses the Alarm Bell output
to annunciate the arming and disarming of an area by
remote means, such as by keyswitch, key fob, or
remote software (RPS, BIS Security Engine). When
arming occurs, the output pulses for two seconds.
When disarming occurs, the output pulses ON, OFF,
ON, OFF for two seconds each.
Abort Window
Prompts:
CC# Abort
Display, P
# Alarm Abort
,
Abort Window
This feature is always enabled, but it only applies to
intrusion alarm events generated by points that have
P# Alarm Abort
set to Yes and
P## Invisible Pt
set
to No. When an intrusion alarm event is annunciated,
the user has the duration of time programmed in the
Abort Window
prompt to enter a valid passcode to
prevent the alarm event from being transmitted to the
central station. When transmission is aborted
successfully, any keypad with
CC# Abort Display
set
to Yes shows ALARM NOT SENT.
Cancel Window
Prompt:
CC# Cancel Display
The burglary alarm cancel window is enhanced by an
optional keypad display. When
CC# Cancel Display
is set to Yes and
Cancel Report
is set to Yes, an
alarm silence operation after event transmission
displays CANCEL RPT SENT on the keypad. The
burglary alarm cancel window duration is the time
programmed in the
A# Alarm Bell
prompt.
Duress Passcode
Prompts:
Duress Type
,
A# Duress Enable
,
L## Send Duress
A new duress option is available that allows any
passcode with the
L# Send Duress
permission set to
Yes to always send a Duress Alarm event upon entry.
This feature allows the control panel to have uniquely
dedicated passcodes for all users. Additionally, when
this feature is enabled, the Passcode +1 and +2
features are disabled for compliance with SIA CP-01-
2000 regulations.
Swinger Shunt Enhancement
Prompt:
Swinger Count
The Swinger Bypass feature is enhanced to allow a
variable number of faults before automatically
bypassing a point. When a point with
P# Swinger
Bypass
set to Yes is faulted the number of times
programmed in
Swinger Bypass Count
, it is
automatically bypassed.
Power-Up Standby
When the control panel is powered up, or the system
is rebooted, all points are now temporarily bypassed
for 60 seconds. This feature is always enabled and has
no configuration parameters.
Walk Test Enhancements
The Walk Test procedure is enhanced to provide
more user feedback. The Walk Test now indicates that
the menu is ready to time out, and clearly notifies the
user at all keypads in the area of operation when a test
is in progress. Additionally, the Walk Test procedure
issues point trouble conditions for any 24-hour points
that remain off-normal when the Walk Test menu idle
time expires. These enhancements are always enabled
and have no configuration parameters.
3.2 Version 7.01
3.2.1 D1260 Keypad Enhancements
The D1260 Keypad must have firmware version 1.03
or above to operate with the GV2 Series Control
Panels. An update kit (P/N: R19-D1260-0103) is available
from Customer Service: (800) 289-0096.
Custom Function Enhancements: The custom
functions now support the soft keys (the eight
unmarked keys around the display) on the D1260
Keypad. This change makes the operation of custom
functions on D1260 Keypad easier to program.
D1260 Keypads with firmware version 1.03 or above
do not need to check the control panel firmware
revision when communicating with GV2 Series
Control Panels; therefore, the Display Revision
(COMMAND 59) keypad (command center) function
can be password protected.
The D1260 and D1260B Keypads can be used with
CC# Supervision
set to No to allow multiple
Enhanced Keypads at the same address.