D9412GV2/D7412GV2
D9412GV2/D7412GV2 Release Notes for Version 7.05
F01U003637-02 Page 8 © 2007 Bosch Security Systems, Inc.
3.2.2 New Firmware Features:
Two Man Rule: Two Man Rule requires two unique
passcodes to be entered at the same keypad to disarm
an area. Without the second passcode, the system
denies entry. Two Man Rule requires the presence of
two people at opening, providing added security.
Early Ambush: Early Ambush requires two passcode
entries on the same keypad or on two separate
keypads located in the same area. Enter the same
passcode twice or enter two unique passcodes,
depending upon the configuration. The first entry
disarms the area and the second entry stops a timer
programmed to send a duress event. If the second
entry does not occur within the preset time, the system
generates a duress event. Early Ambush allows users
to inspect the premises and use the system to confirm
that the area is safe to enter, providing added security.
Easy Exit Control:
The GV2 Series Control Panels change from one
armed state to another armed state without disarming.
For example, if you change the state from Master Arm
to Perimeter Arm, the control panel complies and
reports the change. Easy Exit Control reduces the
number of keystrokes and simplifies system operation.
Passcode-controlled Menus: The system prompts a
user to enter a passcode before viewing the keypad
function list menu. The system shows the user the
menu options allowed according to the user’s authority
level. Passcode-controlled menus simplify system
operation by providing a user with unique and
pertinent options and information. This feature is not
intended for use on D1256 Fire Keypads.
Passcode Follows Scope: Use Passcode Follows
Scope to restrict passcode arming and disarming only
to the keypad’s immediate local area. Passcode
Follows Scope simplifies the arming and disarming
procedure without limiting any other keypad
command capabilities.
Invisible Walk Test: A function list menu item allows
the user to test invisible interior- or perimeter-
controlled and non-controlled (24-hr) points within the
scope of the keypad without sending a report to the
central station.
Door Activated Custom Function: A custom
function activates when user credentials are presented
to the reader of a D9210B Access Control Interface
Module. A custom function behaves as though the
user performed a function at the keypad associated
with the door controller. This feature is available only
on the D9412GV2 and D7412GV2.
Latest Close Time: The Extend Close
(COMMAND 51) function is enhanced with a
programmable latest closing time.
4.0 Upgrading to a GV2 Series
Control Panel
Remote Programming Software (RPS) version 3.7.160
or above is required to upgrade an existing G Series
Control Panel installation to a GV2 Series Control
Panel. Because the GV2MAIN and GV2AUX
handlers cannot read the configuration data from a G
Series Control Panel, using RPS is the only method
available to convert an account’s existing panel type to
a D9412GV2 or D7412GV2.
Refer to the RPS help files for the specific control
panel for additional information on control panel
conversion. In the RPS help file, select:
Panel Specific Information9000 Series
Control/CommunicatorsCommunicating with
9000 Series PanelsUpgrading a Panel Type
Hardware Enhancements
The control panel has an SDI bus quick-connect
terminal (Molex
®
connector) next to the S1 reset
switch. This connector provides an easy way to
connect an SDI device to the SDI bus without
disconnecting the wires on SDI Terminals 29
through 32. To order SDI wiring harnesses, use
the following part numbers: Molex to Molex
(P/N: C321) and Molex to terminal
(P/N: PKWH).
This SDI terminal is not compatible with
the D5200 Programmer.
Two new posts next to the on-board telephone
jack allow easy connection of a butt set or
telephone for troubleshooting purposes. The posts
are labeled TIP and RING.
The telephone line supervision time might
be affected when a butt set or telephone is
connected to the telephone terminal posts.
On-board Relays B (Terminal 7, labeled Alt
Alarm) and C (Terminal 8, labeled SW Aux) are
now installed in the factory. No supplemental
installation or purchase is necessary to prepare
these terminals for use.