AXIS Communications
28-9
P5522 If an Axis P5522 PTZ camera is not receiving sufficient power for
its PTZ operations then it will disable the PTZ motor and remove
the PTZ.Limits and PTZ.Support parameter groups from the
camera parameter list. As a consequence, no PTZ controls will
be available in the NVR web client and Victor Client for that
camera. The symptom may also occur when other PTZ camera
models receive insufficient power.
Q1910,Q1921 The default palette setting of an Axis Q1910 or Q1921 thermal
camera can only be changed by using the camera’s web
interface “Setup -> Video & Audio -> VideoStream -> Image
Appearance.Palette”. Changing the default palette has no effect
on established streams. The NVR uses whatever the default
palette is when the stream is established. After the customer
changes the default palette then it is necessary to destroy and
recreate the stream received by the NVR. The stream can be
destroyed and recreated by simply using the NVR web client to
change the video frame rate.
M5013, M5014 The Axis M5013 and M5014 have a single speed PTZ movement
therefore the camera PTZ movement is affected only by the
interval between the start and stop commands from Victor Client,
not the speed values in the start command. The consequence is
that PTZ movements may be larger than desired. Refer to QC
9770 for more details.
P8221 1 When added to the NVR the device cannot be seen on
the video list as it does not support video stream. The
user must go to the audio list to see the device listed
2 When added to NVR, the firmware for this device
displays as “UNSUPPORTED” until the audio device is
enabled. Use the following steps to do this:
a Add camera to NVR
b Select “Audio List” tab
c Select edit icon
d Select “Enable” from drop down menu
e Save
3 When the P8221 is added to the NVR but is offline, the
settings can still be accessed but will appear as
“unsupported”]
4 As Video Edge 4.4 dry contact is only associated with
video, P8221 Audio I/O module dry contact cannot be
used as this device does not support video stream.
5 As Video Edge 4.4 PTZ is associated with video, P8221
PTZ feature cannot be used as this device does not
support video stream.