84 en | Installing the In-Ceiling Mount VG4 Modular Camera Series
F.01U.162.025 | 6.0 | 2010.03 Installation Manual Bosch Security Systems, Inc.
Bubble Removal
To service the In-Ceiling AutoDome, use the following procedure to remove the Bubble:
1. Loosen the lockscrew (item 1 in the illustration below) in the trim ring using a P1 or
smaller Phillips screwdriver until the bubble can rotate freely.
2. Then rotate the bubble counterclockwise approximately 1/4 turn until it releases from
the In-Ceiling Housing. See the figure below for an illustration.
Figure 4.14 Bubble Release Screw