14.3.1 Entering Test Mode
Place the detector in Test Mode. In Test Mode, the detector’s LED
disable switch (Item 8, Figure 19 on page 51) is overridden. You
can enter the Test Mode locally or remotely.
To enter the Test Mode locally:
1. Carefully open the service door of the detector.
2. Insert a screwdriver into the slot next to the sensitivity
switches that contains the test pads (Item 1, Figure 20 on
page 53).
3. Touch both test pads at the same time with the tip of the
screwdriver.
The Event LED (green) (Item 6, Figure 19 on page 51) flashes
once per sec. If the green LED does not flash, repeat Steps 2
and 3.
The 13-332 Sound Sensor Tester produces extremely
loud sounds and can be hazardous to hearing when used
at close range. Do not point the 13-332 towards
someone’s head.
To enter the Test Mode remotely:
1. Stand within 3 m (10 ft) of the detector.
2. Move the switches on top of the 13-332 Tester to ACTIVATE
and to MAN modes (Items 1 and 3, Figure 21 on page 54).
3. Point the front of the tester towards the detector and press
the red Start button on top (Item 2, Figure 21 on page 54).
The tester buzzes and the green LED on the detector flashes once
per sec. If the green LED does not flash, move closer to the
detector and repeat the procedure.