K2200 Series | Installation Guide | 5.0 Installation Details EN | 39
Bosch Security Systems | 7/03 | 17375 1.3 / 46513C
5.5.4 Alarm Event Manager
An Alarm Event Manager (AEM) can be connected to the reader channel of any of the door controllers.
Figure 26: AEM Cable Distances
1
2
3
4
5
Max Distance: 1000 m (3000 ft.)
Max Distance:
500 m (1500 ft.)
1 - Door Controller
2 - Alarm Event Manager
3 - Reader
4 - 8 Supervised Inputs
5 -- 8 Outputs
Inputs
There are 8 supervised inputs available on the AEM.
The detectors may be either Normally Closed or
Normally Open. The type of detector is set using the
switch bank on the left of the circuit board, below the
tamper switch.
For more details, refer to the documentation supplied
with the AEM.
5.5.5 26-bit Wiegand Readers
Most 26-bit Wiegand readers with open collector D0,
D1 can be connected to a Readykey K2200 Series
Door Controller as shown in Figure 27 and Figure 28.
Note that an interface kit is not required.
Figure 27: Wiegand Connections – 18 V
Figure 28: Wiegan Connections – 12 – 30 V
This is for caption text
5.5.6 Magstripe Readers
Magstripe readers with open collector CLK, DATA
can be connected to a Readykey
K2200 Series Door
Controller as shown in Figure 29. Note that an
interface kit is not required.