12.0 SDI Devices
12.1 Description
The D7212GV2 Control Panel can support a number
of accessory devices from the SDI Bus using Terminals
29 through 32. Some devices include the D1255RB and
D1255 Keypads (refer to Section 11.0 Arming Devices on
page 46), D9131A Parallel Printer Interface Module,
DX4010i RS-232 Serial Interface Module, and DX4020
Network Interface Module.
12.2 Installation
For complete installation instructions, consult the
operation and installation guide for the specific SDI
device. SDI devices connect to the control panel in
parallel (Table 20).
These devices can share power with the control panel
or be powered by a stand-alone power source.
Table 20: SDI Device Connections
D7212GV2 SDI Devices
Terminal Function Wire Color Function
32 POWER + Red +12 VDC
31 DATA BUS 1 Yellow Data – In
30 DATABUS B Green Data – Out
29 COMMON Black Common
A stand-alone power supply powering the
SDI device must also be connected to a
common terminal on the control panel.
Do not connect the earth ground for the
stand-alone power supply to Terminal 10
on the control panel.
12.3 D9131A Parallel Printer Interface
Module
The Bosch Security Systems, Inc. D9131A Parallel
Printer Interface Module is a four-wire powered device
used to connect a standard parallel printer to a control
panel. The D7212GV2 can supervise one printer. A
separate D9131A Parallel Printer Interface Module is
necessary for each printer. The D9131A connects to
the printer using a standard parallel printer cable.
12.3.1 Switch Settings
Switches on the D9131A assign a unique address (17 to
19) for each printer. The address determines if the
printer is supervised, the area scope of the printers, and
the area to which the printer is assigned. Refer to
Printer Parameters in the D7212GV2 Program Entry Guide
(P/N: F01U003804) for a complete description of
addresses.
Table 21 shows the correct switch setting for Address
17.
Table 21: Printer Address Switch Settings
Printer Switch
1 2 3
4
5 6
17 ON ON ON ON ON ON
Switch 4:
ON = Header and form feed
OFF = No header and form feed
12.3.2 Supervision
Supervision includes:
Proper operation of the SDI bus
Proper connection of the printer cable between
the printer and the D9131A
Printer paper supply
Printer selected (on-line)
Printer power.
The control panel sends an SDI Failure Report to the
receiver if communication with the printer interface
fails. If an SDI failure occurs,
SERVC PRINTER
appears at the keypad. The report to the receiver
includes the address of the troubled D9131A to
indicate which printer needs service.
If an SDI device is supervised and Terminal SDI A
becomes disconnected, the device can continue to
operate normally, depending upon environmental
conditions.
12.4 SDI Address 80
SDI Address 80, available on the D7212GV2 Control
Panel, allows for two-way SDI to RS-232 information.
This address is used with home or building automation
software.
12.4.1 Serial Interface Module (SIM)
The DX4010i RS-232 Serial Interface Module and
D9133 Serial Interface Module are four-wire powered
SDI device that connect RS-232 devices to the
D7212GV2 Control Panel. The DX4010i uses a
specific communication protocol that is provided upon
request. Contact Bosch Security Systems, Inc.
Technical Support Monday through Friday from 5 AM
to 5 PM EST at 888-886-6189.