Bosch DS7400XiV4-EXP Dokumentacja Strona 69

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 68
DS7400XiV4-EXP | Reference Guide | 5.0 Programming the Control Panel EN | 69
Bosch Security Systems | 1/05| 4998154963B
5.9.30 Phone Number General Control Programming
See Section 7.2.14 Phone Number General Control Programming for Phone Number General Control glossary
definitions.
Address: 3155
Data Digit:
Data Digit 1: ____ (see Table 94; default = 2)
Data Digit 2: ____ (see Table 95; default = 0)
Selections: 0 to 9, *0 to *5 (hexadecimal values that display as A through F at the keypads)
Table 94: Address 3155, Data Digit 1)
Selections for Data Digit 1
Select Options 0 1 2 3 4 5 6 7 8 9 *0 *1
Enable remote programmer call-back
Dial pulse on all phone numbers
Dial tone on all phone numbers
1
Dial tone, switch to pulse if required
Try DS7416i first
2
Table 95: Address 3155, Data Digit 2)
Selections for Data Digit 1
Select Options 0 1 2 3 4 5 6 7 8 9 *0 *1 *2 *3 *4 *5
Dialer delay of 15 seconds on non-24-hour burglar
alarms only
3
Dialer delay of 15 seconds on 24-hour burglar and fire
alarms only
3
Send alarms using either DS7416i or digital
4
Send alarms using both DS7416i and digital
2, 4
Use 110 baud communication for RPS
Use 300 baud communication for RPS
1
Required on PBX systems.
2
If this option is selected, see Section 5.9.28 Phone/DS7416i Routing Control (Program Addresses 3153 and 3154).
3
These selections can only be used with systems that have only one area.
4
Only applicable when using the DS7416i option.
Przeglądanie stron 68
1 2 ... 64 65 66 67 68 69 70 71 72 73 74 ... 143 144

Komentarze do niniejszej Instrukcji

Brak uwag