Table 107: Octal Relay Address B Selections
Selections for
Data Digits 1 & 2
Follow System Wide Event
Select Options
DD1 DD2
Disabled 0 0
AC Power Fail 0 1
Low Battery 0 2
Communicator Failure 0 3
System Fault
1
0 4
Keypad Supervision Fault 0 5
Multiplex Bus Fault 0 6
RF Receiver Fault 0 7
Aux Power Fault 0 8
Fire Zone Trouble 0 9
Supervisory 0 *0
Zone Trouble 0 *1
Duress 0 *2
Battery Test 0 *3
Future Selection 0 *4
Future Selection 0 *5
1
System Faults include:
• RAM fault • Serial Transmit fault
• ROM fault • Serial Receive fault
• Bell/Line Monitor fault • Aux. Relay fault
• Line 1 fault
• Alternate
Communication fault
• Line 2 fault • RF Receiver Tamper
• Bell fault • RF Receiver Jammed
• Aux Power fault • RF Receiver Trouble
• Octal Relay fault • Printer Off-line
• Serial Module fault
Follow Function (Addresses 2740 to (2771)
• Program Address A: 2740 to 2770
• Data Digit:
• Data Digit 1:
3 (default = 1)
• Data Digit 2: ____ (default = 3)
• Program Address B: 2741 to 2771
• Data Digit:
• Data Digit 1: ____ (default = 0)
• Data Digit 2: ____ (default = 6)
To program an Octal Relay Module for Follow Output
Function:
1. Select the Octal Relay to program (see Table 108).
2. Program Data Digit 1 of Program Address A as 3
for Follow Function.
3. Program Data Digit 2 of Program Address A for
the desired function (see Table 109).
4. Program Data Digit 1 and 2 of Program Address B
for the desired function (see Table 110).
5. Once both Address A and Address B have been
programmed, proceed to program the next Octal
Relay.
For Octal Relay Partition Assignment information, see
Octal Relay Module Output Partition Assignment (Addresses
2844 to 2851) on page 80.
For output function information, see Section 5.9.37
Output Function Programming on page 81.
Table 108: Octal Relay Program Addresses
DX3010-1 Octal Relay
Number
Address A
(see Table 109)
Address B
(see Table 110)
1 2740
3
2741
2 2742
3
2743
3 2744
3
2745
4 2746
3
2747
5 2748
3
2749
6 2750
3
2751
7 2752
3
2753
8 2754
3
2755
9 2756
3
2757
10 2758
3
2759
11 2760
3
2761
12 2762
3
2763
13 2764
3
2765
14 2766
3
2767
15 2768
3
2769
16 2770
3
2771
Table 109: Octal Relay Address A Selections
Selections for
Data Digit 2
Follow Function Select Options 0 1 2 3
Disabled
•
Burglar Alarm
•
•
Fire Alarm
• •
Komentarze do niniejszej Instrukcji