Bosch DS7400XiV4-EXP Dokumentacja Strona 76

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 75
DS7400XiV4-EXP | Reference Guide | 5.0 Programming the Control Panel EN | 76
Bosch Security Systems | 1/05| 4998154963B
Table 107: Octal Relay Address B Selections
Selections for
Data Digits 1 & 2
Follow System Wide Event
Select Options
DD1 DD2
Disabled 0 0
AC Power Fail 0 1
Low Battery 0 2
Communicator Failure 0 3
System Fault
1
0 4
Keypad Supervision Fault 0 5
Multiplex Bus Fault 0 6
RF Receiver Fault 0 7
Aux Power Fault 0 8
Fire Zone Trouble 0 9
Supervisory 0 *0
Zone Trouble 0 *1
Duress 0 *2
Battery Test 0 *3
Future Selection 0 *4
Future Selection 0 *5
1
System Faults include:
RAM fault Serial Transmit fault
ROM fault Serial Receive fault
Bell/Line Monitor fault Aux. Relay fault
Line 1 fault
Alternate
Communication fault
Line 2 fault RF Receiver Tamper
Bell fault RF Receiver Jammed
Aux Power fault RF Receiver Trouble
Octal Relay fault Printer Off-line
Serial Module fault
Follow Function (Addresses 2740 to (2771)
Program Address A: 2740 to 2770
Data Digit:
Data Digit 1:
3 (default = 1)
Data Digit 2: ____ (default = 3)
Program Address B: 2741 to 2771
Data Digit:
Data Digit 1: ____ (default = 0)
Data Digit 2: ____ (default = 6)
To program an Octal Relay Module for Follow Output
Function:
1. Select the Octal Relay to program (see Table 108).
2. Program Data Digit 1 of Program Address A as 3
for Follow Function.
3. Program Data Digit 2 of Program Address A for
the desired function (see Table 109).
4. Program Data Digit 1 and 2 of Program Address B
for the desired function (see Table 110).
5. Once both Address A and Address B have been
programmed, proceed to program the next Octal
Relay.
For Octal Relay Partition Assignment information, see
Octal Relay Module Output Partition Assignment (Addresses
2844 to 2851) on page 80.
For output function information, see Section 5.9.37
Output Function Programming on page 81.
Table 108: Octal Relay Program Addresses
DX3010-1 Octal Relay
Number
Address A
(see Table 109)
Address B
(see Table 110)
1 2740
3
2741
2 2742
3
2743
3 2744
3
2745
4 2746
3
2747
5 2748
3
2749
6 2750
3
2751
7 2752
3
2753
8 2754
3
2755
9 2756
3
2757
10 2758
3
2759
11 2760
3
2761
12 2762
3
2763
13 2764
3
2765
14 2766
3
2767
15 2768
3
2769
16 2770
3
2771
Table 109: Octal Relay Address A Selections
Selections for
Data Digit 2
Follow Function Select Options 0 1 2 3
Disabled
Burglar Alarm
Fire Alarm
Przeglądanie stron 75