DS7400XiV4-EXP | Reference Guide | 5.0 Programming the Control Panel EN | 90
Bosch Security Systems | 1/05| 4998154963B
Test Report Minute
Address: 4023
Data Digit:
Data Digit 1: ____ (default = 0)
Data Digit 2: ____ (default = 0)
Selections: 0 to 5 for Data Digit 1; 0 to 9 for Data
Digit 2
Default: 00
Call-Out Hour
Address: 4024
Data Digit:
Data Digit 1: ____ (default = 0)
Data Digit 2: ____ (default = 0)
Selections: 0 to 2 for Data Digit 1; 0 to 3 for Data
Digit 2
Default: 00
Call-Out Minute
Address: 4025
Data Digit:
Data Digit 1: ____ (default = 0)
Data Digit 2: ____ (default = 0)
Selections: 0 to 5 for Data Digit 1; 0 to 9 for Data
Digit 2
Default: 00
5.9.41 Test Report and Remote Programmer Call-
Out Programming
This section allows you to define the Day and
Frequency for the Communicator Test Report and the
Remote Programmer Call-Out.
If this address is not programmed, the Communicator
Test Report is not sent and the control panel does not
call the Remote Programmer.
Address: 4026
Data Digit:
Data Digit 1: ____ (default = 0; see Table 130)
Data Digit 2: ____ (default = 0; see Table 131)
Selections: 0 to *2 for Data Digit 1; 0 to *0 for
Data Digit 2
*0 through *2 are Hex values. They display
as A through C at the keypads.
Table 130: Address 4026, Data Digit 1 Selection
Options
Select Option Value
Do not send a Test Report
0
Send a Test Report on Sunday 1
Send a Test Report on Monday 2
Send a Test Report on Tuesday 3
Send a Test Report on Wednesday 4
Send a Test Report on Thursday 5
Send a Test Report on Friday 6
Send a Test Report on Saturday 7
Send a Test Report every day 8
Send a Test Report every 8 days 9
Send a Test Report every 28 days *0
Send a Test Report every hour *1
Send a Test Report every 12 hours *2