DS7240/DS7220 User's Guide Copyright 2002 Detection Systems, Inc. P/N: 49211C Page 49
PART III: REFERENCE MATERIALS
Event
#
Event Description Event
#
Event Description
81 Fire, Trbl, Rstl
Restoral from Trouble, fire
detection device(s).
101 Bad Call to RPS
Panel attempted to call DS-RPS, but was
unsuccessful.
82 Instl Mode, Start Installer PIN entered. Installer
Mode accessed.
102 RPS Access Fail DS-RPS attempted to connect to panel, but
was unsuccessful.
83 Instl Mode, End Installer Mode exited. 103 RPS Access OK DS-RPS successfully connected to and
disconnected from panel.
84 Log Overflow
Panel log overflow condition.
Oldest events being overwritten.
104 Re-boot, Panel Normal start-up or reset with Installer Switch.
85 Log Threshold Panel log reached threshold.
Contact Security Company.
105 Re-Boot, Dbus Unexpected reset (reboot) from Data Bus
device.
86 AltCom Low Signl
Low signal strength detected on
alternate communication device.
106 Output Reset, Usr Relay reset by user.
87 Missing, Alarm Zone assigned to zone expander
(wired or RF) not responding to
panel’s status poll while system is
armed.
107 Output Reset, Skd Relay reset by Sked.
88 Missing, Trouble Zone assigned to zone expander
(wired or RF) not responding to
panel’s status poll while system is
disarmed.
108 Output Reset,
RPS
Relay reset by DS-RPS.
89 Open, Skd Opening by Sked. 109 Output Set, Usr Relay set by user.
90 Open, RPS Opening by DS-RPS. 110 Output Set, Skd Relay set by Sked.
91 Open, User Opening by user, ID reported. 111 Output Set, RPS Relay set by DS-RPS.
92 Open, KS Opening by keyswitch. 112 Rstrl, Tamper Restoral from alarm, Tamper zone type.
93 Open, Skd, Alarm Opening after alarm event by
Sked.
113 Rstrl, Emergency Restoral from alarm, Emergency zone type.
94 Open, RPS,
Alarm
Opening after alarm event by DS-
RPS.
114 Rstrl, Panic Restoral from alarm, Panic zone type.
95 Open, Usr, Alarm Opening after alarm event by user,
ID reported.
115 Rstrl, Invisible Restoral from alarm, Invisible zone type.
96 Open, KS, Alarm
Opening after alarm event by
keyswitch.
116 Rstrl, 24-hr Burg Restoral from alarm, 24-hr Burglary zone type.
97 Reserved. 117 Rstrl, Cntrl, Dly Restoral from alarm, Controlled zone type.
98 Params Changed Panel parameters changed. 118 Rstrl, Cntrl, Dly Restoral from alarm, Controlled zone type.
99 Phone Line Fail Phone line voltage falls below
threshold for 40 seconds.
119 Rcvr Jam Jammed condition detected on premises RF
Receiver.
100 Phone Line Rstl
After Phone Line Fail event, phone
line voltage detected above
threshold for 40 seconds.
120 Rcvr Jam Rstl
Jammed condition detected on premises RF
Receiver cleared.
Table 18 (cont.): Panel Event Descriptions
Przeglądanie stron 48