4.2 Programming Area Names
When the D1260 is installed with D9412G, D7412G, D9412, D7412, D7212, and D9112 Control/Communicators, Points
240 to 247 are used for the Area Text Name for the Area (1 to 8) that the D1260 is assigned to. When the D1260 is
installed with the D7212G Control/Communicator, Points 240 to 243 can be used for Area Text Name for the Area (1 to
4) that the D1260 is assigned to.
Note: These points can still be used in D9412 and D9112 systems to detect alarms, although any custom point text that
is point specific will be displayed as the Area Name Text.
Area # Point # Area Name Text – up to 16 characters
1* 240 __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __
2* 241 __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __
3* 242 __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __
4* 243 __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __
5 244 __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __
6 245 __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __
7 246 __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __
8 247 __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __
*D7212G uses Points 240 to 243 for Area Name Text.
For example, if a D1260 is assigned to Area
1, and the name of Area 1 is
“WAREHOUSE,” then you would program
the word “WAREHOUSE” into Point 240.
See Table 8 for Area Name Text
assignments. This point text is used in the
D9412G/D9412/D9112 and
D7412G/D7412/D7212G/D7212 Control
Communicators to program the Area
Names.
4.3 Programming Security
Co. Info
Table 8: Area and Point Numbers and Area Name Text
When accessing the Help? function on the D1260, there is a menu item called Security Co. Info. Within this menu is the
ability to program your security company’s phone number in the event a subscriber needs to contact you. For the
D9412G, D9412, and D9112, the text programmed for User 249 Name (use RADXUSR2) is what will be displayed on this
screen. For the D7412G, D7412, D7212G, and D7212, the D1260 uses the text programmed in User 99’s Name (use
RADXUSR1 handler) text.
4.4 99 + Enter “Setup?” Function
The Setup function is accessed by pressing [9] [9] [Enter], Next>, then press the Setup?> soft key.
The adjustable functions that are available in this menu are
High Brightness, Low Brightness, and Contrast.
Each of these selections have <- Level +> soft keys on either side of the display that allows you to increase (+) or decrease
(-) the setting being displayed. The High and Low Brightness are associated to Command 49’s Bright Display and Dim
Display settings.
Also shown in this menu is the Command Center address,
whether the Encoding Tone is On or Off,
and the Command Center software revision.