5. Set the J1 jumper on the TXB-B to the proper termination setting (refer to Figure 13). Note the
following:
• By default, the J1 jumper is installed in the terminated position.
• All TXB-Bs in a daisy chain, except the last unit, must be unterminated.
• The total wire distance from the Bosch (Philips, Burle) controller to the last TXB-B in a daisy
chain must be less than 4,000 ft (1,219 m).
• A maximum of 10 receivers can be installed on a single daisy chain.
• To unterminate a TXB-B, remove the J1 jumper from the TXB-B and place it over one pin for
storage.
Figure 13. TXB-B Termination and DIP Switch
6. Set the address of the TXB-B (refer to Table C, Table D, and Table E in the Appendix beginning on
page 26).
7. Install the TXB-B translator board (refer to Figure 14 and Figure 15 on page 15):
a. Remove the cover from the top of the dome drive.
b. Remove the shorting plug from the 16-pin connector located on the Spectra Mini dome circuit
board.
NOTES:
• Discard the 6-32 and 4-40 screws and their lock washers; they are not used in the
Spectra Mini dome.
• Save the 16-pin shorting plug and the original cover from the Spectra Mini dome. Other-
wise, the unit cannot be converted back to a Pelco-controlled system.
16-PIN CONNECTOR
TXB-B
ADDRESS
SWITCH
J1 RESET FOR LOOPING (UNTERMINATED)
OPERATION
FRONT BACK
J1 TERMINATED
J1 UNTERMINATED