ON 17 Enter Set fixed speed 46°/sec
OFF 17 Enter Acknowledge alarm
ON 18 Enter Set fixed speed 60.1°/sec
OFF 18 Enter No action**
ON/OFF 20 Enter No action**
ON/OFF 21 Enter Set zone 1 start/end
ON/OFF 22 Enter Set zone 2 start/end
ON/OFF 23 Enter Set zone 3 start/end
ON/OFF 24 Enter Set zone 4 start/end
ON/OFF 25 Enter Set zone 5 start/end
ON/OFF 26 Enter Set zone 6 start/end
ON/OFF 27 Enter Set zone 7 start/end
ON/OFF 28 Enter Set zone 8 start/end
ON/OFF 30 Enter No action**
ON/OFF 31 Enter No action
ON/OFF 32 Enter No action
ON/OFF 33 Enter No action
ON/OFF 34 Enter No action
ON 35 Enter No action
OFF 35 Enter No action
ON 39 Enter IR filter, insert Call preset 88
OFF 39 Enter IR filter, remove Call preset 89
ON 40 Enter Manual left limit stop
ON 41 Enter Manual right limit stop
OFF 41 Enter No action**
ON 42 Enter Scan left limit stop
OFF 42 Enter No action**
ON 43 Enter Scan right limit stop
OFF 43 Enter No action**
ON 44 Enter Move to factory home
OFF 44 Enter Recalibrate camera
ON 45 Enter Display program menu** Call preset 95
OFF 45 Enter No action
ON/OFF 46 Enter Stop a scan Call preset 96
ON 47 Enter Random scan Call preset 97
ON 48 Enter Frame scan Call preset 98
ON 49 Enter Auto scan Call preset 99
ON 50 Enter Runs long pattern Call long pattern
OFF 50 Enter Stops pattern Stop long pattern
ON/OFF 51 Enter Run/stop pattern 1 Call pattern 1
ON/OFF 52 Enter Run/stop pattern 2 Call pattern 2
ON/OFF 53 Enter Program long pattern Set long pattern