18 C2431M-I (4/07)
Figure 18. TXB-B Termination and DIP Switch
4. Set the address of the TXB-B (refer to Table C, Table D, and Table E in the Appendix begining on
page 26).
5. Install the TXB-B board on the power module (refer to Figure 19):
a. Remove the shorting plug from the 16-pin connector located on the ExSite’s circuit board.
NOTES:
• Discard the 6-32 and 4-40 screws and their lock washers; they are not used in the
ExSite.
• Save the 16-pin shorting plug. Otherwise, the ExSite cannot be converted back to a
Pelco-controlled system.
b. Insert the TXB-B board into the 16-pin connector located on the ExSite system’s circuit board.
Confirm that the TXB-B board is fully seated into the 16-pin connector.
Figure 19. Installing the TXB-B into the ExSite
16-PIN CONNECTOR
TXB-B
ADDRESS
SWITCH
J1 RESET FOR LOOPING (UNTERMINATED)
OPERATION
FRONT BACK
J1 TERMINATED
J1 UNTERMINATED
16-PIN
CONNECTOR
SW1 SW3