DCN Next Generation Open Interface Release 2.4 Microphone Management
en | 107
Bosch Communications Systems | 2007 February | SRS_MMINF | Du020903
3.8.3 MM_C_TIME_FINISHED_WARNING
Purpose
This function is used to inform a particular unit that its time to speak is run out.
Parameter structure for the function
This function has one parameter:
WORD wUnitId;
where:
wUnitId The unit on which to place the message.
Response structure from the function
This function has no response parameters.
Error codes returned
MM_E_NOERROR
MM_E_UNKNOWN_UNIT
Related functions
MM_C_SET_SPEECHTIME_SETTINGS
MM_C_LAST_MINUTE_WARNING