DCN Next Generation Open Interface Release 2.4 Microphone Management
en | 122
Bosch Communications Systems | 2007 February | SRS_MMINF | Du020903
APPENDIX C. EXAMPLES
In the example below the remote functions and update notifications, that are defined in this
document as constant values for the wFnId parameter of the message (see [SRS_INF]), are
presented as functions described in a ‘C’ syntax. The parameter structures of these functions
are according the input, output or notify structures described in the appropriate section.
For every function is assumed that the function will create his structure, transport the
parameters to the CCU and waits for the result information coming from the CCU.
For both the remote functions as the update notifications the same names are used as their
identifier, but without the constant mark “C” and using mixed case names. So, e.g. remote
function MM_C_SET_SETTINGS shall be referenced as function as:
MM_Set_Settings (MM_T_CCU_GLOBAL_SETTINGS tMMSettings);
Appendix C.1 Microphone Management Control
This example shows the minimum steps to be taken for controlling the MM application.
First we have to start the MM application inside the CCU.
WORD wNrOfInstances;
error = MM_Start_MM(&wNrOfInstances);
if (error != MM_E_NOERROR)
{
/* do error handling */
}
else
{
switch (wNrOfInstances)
{
case 0 : /* something went wrong with registering for remote
interface
so, do error handling */
break;
case 1 : /* OK */
break;
default : /* 2 or more. This means there are more remote controllers
identified by the CCU. Stop as many times as needed */
WORD wNewNumber;
do
{
MM_Stop_MM(&wNewNumber);
} while (wNewNumber > 1);
break;
}
}
If there are no errors on starting the MM application the next thing we are interested in are the
settings. Assume that we want the system to operate in a Operator with RTS list mode, 4
active mics and a maximum RTS list length of 50. The first thing to do is retrieve the current
settings, then check them against the wanted settings and, if they are not the same, set the
new settings.
The results in the following control flow:
/* declare variables */
MM_T_CCU_GLOBAL_SETTINGS tMMSettings;
BOOLEAN bMustSend = FALSE;
/* retrieve the current settings */
MM_Get_Settings(&tMMSettings);
/* and check if they are what we want */
if (tMMSettings.wOperationMode != MM_C_OPERATOR_WITH_REQ_LIST)
{
tMMSettings.wOperationMode = MM_C_OPERATOR_WITH_REQ_LIST;
bMustSend = TRUE;
}
if (tMMSettings.wActiveMics != 4)