DCN Next Generation Open Interface Release 2.4 Config Install and Database
en | 61
Bosch Communications Systems | 2007 February | SRS_SCSIINF | Du010934
Related functions
SI_C_REQ_OPERATION_MODE
Update notifications
SI_C_OPERATION_MODE
5.13 SI_C_REQ_SLAVE_ID
Purpose
Request the slave identification of the unit. After executing this function, a notification will be
send for each known unit.
Availability
This function is available in system mode: CONFIG.
Parameter structure for the function
This function requires the structure SI_T_SERIALNR_LIST as parameter. This structure is
defined in section xxx.
Response structure from the function
The function has no response parameters.
Error codes returned
SI_E_NOERROR
Related functions
SI_C_SET_SLAVE_ID
Update notifications
SI_C_SLAVE_ID
5.14 SI_C_SET_SLAVE_ID
Purpose
Set the slave identification of the unit.
Availability
This function is available in system mode: CONFIG.
Parameter structure for the function
The function requires the following structure as parameter:
SI_T_SLAVE_ID tSlaveId;
where:
dwSerialNr The serial number of a unit
dwSlaveId The slave identification of the unit, with the values 0 until and
including 31.
Response structure from the function
The function has no response parameters.
Error codes returned
SI_E_NOERROR
SI_E_WRONG_PARAMETER
SI_E_NOT_CONTROL_UNIT
Related functions
SI_C_REQ_SLAVE_ID
Update notifications
SI_C_SLAVE_ID