DCN Next Generation Open Interface Release 2.4 General
en | 31
Bosch Communications Systems | 2007 February | SRS_INF | Du010933
APPENDIX A. PROTOCOL, SERIAL PORT & TCP/IP SETTING
A.1. Protocol Settings Single CCU (DCN-CCU or DCN-CCUB)
In this Single CCU configuration two serial ports are available. Both ports can be individually
configured.
The default settings for both serial ports are:
• 8 data bits
• No parity check
• 1 stop bit
Port 1
The baudrate for port 1 can be set by setting Dip-Switches 3+4 of as shown in the following
table:
Switch Baudrate Remark
3 4
off off 9.6k
off on 19.2k
on off 57.6k
on on 115.2k
Default
The protocol for port 1 can be set by setting Dip-Switches 1+2 as shown in the following
table:
Switch Protocol Remark
1 2
off off Simple
The serial port is used with the ‘Simple’ feature protocol
as described in §4.1.3.
off on Terminal The serial port is used with an ASCII interface. Expected is
a terminal to do diagnostics on the CCU.
on off Full
The serial port is used with the ‘Full’ feature protocol as
described in §4.1.2. (Default)
on on Camera control The serial port is used for connection to an Allegiant Video
Switcher (AVS) or AutoDome camera (DCC).
Port 2
The baudrate for port 2 can be set by setting Dip-Switches 7+8 of as shown in the following
table:
Switch Baudrate Remark
7 8
off off 9.6k
off on 19.2k
Default
on off 57.6k
on on 115.2k