DCN Next Generation Open Interface Release 2.4 General
en | 34
Bosch Communications Systems | 2007 February | SRS_INF | Du010933
APPENDIX C. ERROR CODES
Responses returned upon a remote function request contain a error field (‘wError’). In this
appendix an overview is given of the possible errors and their values.
Remote Function Services Error code Value
(hex.)
Explanation
RFSE_BADFUNCTIONID
10901
(0x2A95)
The remote function called is not registered by the Remote
Function Services. Either the function does not exist or the
CCU is operating in a wrong mode.
RFSE_ALLOCFAILED
10904
(0x2A98)
The requested data-area for the function response could not
be allocated. The CCU went out of memory during the remote
function call.
RFSE_NOACCESSPERMISSION
10907
(0x2A9B)
The remote function called is not authorized for use, meaning
no license key enabling use of the remote interface function is
present on the CCU.
IPME_INVALID_MESSAGELENGTH
4485152
(0x00447
020)
The overall message length of the data is too small (below 8
bytes) or too large (above 8000 bytes). Please not that this
error code is used only in conjunction with the
MESSAGETYPE_OIP_ResponseProtocolError message.