DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 68
Bosch Security Systems | 8/04 | 4998153891C
Don’t Show Zone Status on Keypads: If the “Don’t Show Zone Status on Keypads” option is not enabled in
the Keypad # Options parameter, the text keypad displays “OK for All On” or “OK for Perimeter Only” across
the second line. This indicates that all zones are normal and the system is ready to arm All On or Perimeter
Only. If a controlled zone is faulted, the Area Idle Text for this zone’s assigned area replaces the “OK for All
On/OK for Perimeter Only” message.
If a zone not configured for Perimeter Only arming is faulted, “OK for Perimeter Only” replaces “OK for All
On” on the text keypad’s display. The system might be armed Perimeter Only, but cannot be armed All On
until the faulted zone is restored.
If the “Don’t Show Zone Status on Keypads” option is enabled, the area idle text displays continuously on line
two when the keypad is idle.
LED keypads do not show zone status if this option is selected.
If the “Don’t Show Zone Status on Keypads” option is selected, the default Area Idle Text (“Not Ready”)
should be changed. See Text Entry Addresses on page 7 for text entry instructions.