4.10 Network Communication
Firmware revision 2.10 or greater is required for network communication.
The control panel can be configured to communicate over an Ethernet network. Reports can be sent over this
network from the control panel to the ARC receiver. Remote programming can also be conducted over this
network. A DX4020 Network Interface Module (NIM) is required for network communication. See “Network
Interface Module (DX4020)” in the DS7200V2 Installer’s Guide (P/N: 4998153893) for installation/configuration
instructions.
Use the following steps to configure the control panel for network communication:
1. Enter an IP address for the ARC receiver [refer to IP Address 1 (2) for Destination 1 (2)].
2. If necessary, enter a port number for the ARC receiver’s IP address (refer to page 130).
3. Set the Alternate Communication Options parameter to “5” (refer to page 132).
4. Set the Network Interface Module Options parameter to “3” (refer to page 135).
IP Address 1 (2) for Destination 1 (2)
• Address:
− IP Address 1, Destination 1: 0000 to 0031
− IP Address 2, Destination 1: 0032 to 0063
− IP Address 1, Destination 2: 0066 to 0097
− IP Address 2, Destination 2: 0098 to 0129
• Default: All zeroes (0)
• Selections: 000.000.000.000 to 255.255.255.255
Each routing destination can be configured as a phone number or an IP address for network communication.
When entering an IP address, only the first 12 digits are used. For example, to enter an IP address of 172.30.1.101
into the Phone 1, Destination 1 addresses, enter the following digits in the first 12 addresses: 1, 7, 2, 0, 3, 0, 0, 0, 1,
1, 0, 1.
See Table 30 for entry selections.
Table 30: IP Address Entry Selections
Digit Enter at Keypad Digit Enter at Keypad
1 [1] 6 [6]
2 [2] 7 [7]
3 [3] 8 [8]
4 [4] 9 [9]
5 [5] 0 [0] or [1][0]