DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 54
Bosch Security Systems | 8/04 | 4998153891C
Authority Level Option 4: Disarming the System
Address: 0367
Default: 15
Selections: 0 to 15
Enter This Data Digit to Select Options
Authority Level Option 4: Disarming the System 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Disarm Not Assigned (see warning below)
Assign to Authority Level 1
• • • • • • • •
Assign to Authority Level 2
Assign to Authority Level 3
• • • • • • • •
Assign to Authority Level 4
• • • • • • • •
This parameter enables/restricts disarming of the system by authority level.
If 0 (Disarm Not Assigned) is selected for Authority Level Option 4 (Address 0367), you cannot disarm
the system from a keypad or RF keyfob. You can still disarm from a Sked, RPS, or a keyswitch.
Authority Level Option 5: One-Time Disarm
Address: 0368
Default: 8
Selections: 0 to 15
Enter This Data Digit to Select Options
Authority Level Option 5: One-Time Disarm 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
One-Time Disarm Not Assigned
Assign to Authority Level 1
• • • • • • • •
Assign to Authority Level 2
Assign to Authority Level 3
• • • • • • • •
Assign to Authority Level 4
• • • • • • • •
If an authority level can disarm the system, use this parameter to restrict that authority level to One-time Disarm
(can only disarm the system once).