DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 61
Bosch Security Systems | 8/04 | 4998153891C
Authority Level Option 15: View Log
• Address: 0378
• Default: 3
• Selections: 0 to 15
Enter This Data Digit to Select Options
Authority Level Option 15: View Log 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
No PIN Required
•
Assign to Authority Level 1
• • • • • • • •
Assign to Authority Level 2
• • • • • • • •
Assign to Authority Level 3
• • • • • • • •
Assign to Authority Level 4
• • • • • • • •
This parameter enables/restricts the View Log function ([#][8][5]) by authority level.
4.4.2 PIN Configuration/Installer PIN
A Personal Identification Number (PIN) is a unique number issued at the time of installation of each system. This
PIN is required to operate the system (arm/disarm, test system, initiate functions, etc.). The PIN is not the same as
the account number.
PIN Length
• Address: 0379
• Default: 4 (4 digits long)
• Selections: 3 to 7 (3 digits min; 7 digits max)
This parameter determines the number of digits in a PIN. All user PINs and the Installer PIN follow this length.
If the PIN length is shortened after PINs are entered, duplicate PINs could be created (for example,
PINs 1235 and 1238 would both become 123).